The COBRA BC 0601 G vacuum pumps are COBRA NW screw

vacuum pumps with cooling water and nitrogen circuits.
The COBRA NS screw vacuum pumps are driven by water-cooled 

motors.

Principle of DP vacuum pumps

The COBRA NS screw vacuum pumps work by the principle of spiral

pumps. Two parallel screws (8) rotate in opposite directions in the

pump body. Entering gases are trapped between the flights of the 

screws and the pump body. The gases are conveyed by the rotation of

the screws to the exhaust, where they are discharged.

Principle of MB vacuum pumps

The Roots vacuum pumps operate according to the approved principle

of the Roots type machine. Operation is both simple and effective.

Two lobes (9) with identical profiles rotate in opposition directions with

in a casing. As they rotate, gas is drawn into the space between each

lobe and the casing where it is trapped and by the rotation pushed out

into the discharge. This action is repeated twice for each revolution of

each lobe and therefore four times for each revolution of the drive

shaft. There is no mechanical contact between lobes and cylinder. So

no oil lubrication is required.

The drive motor of roots pump is a water cooled canned motor.

Gas flow checks

A pressure sensor PSA at the discharge monitors the discharge

pressure. If the pressure reaches more than the limit value (alarm,

preset at the factory: 0.2 bar), the purge cycle starts.

Oil circuit

Since the complete operating principle works without contact, no oil 

circuit is needed in the work area.

Cooling

The vacuum pump is cooled by

a direct cooling water circuit in the motors and the DP and MB

transmission casing. The flow regulating valve CWR of cooling

water is preset on 3-4 l/min at the factory. The water cools in the

DP and MB pumps motors, the one frequency inverter (VFD 1)

and the drive/ pump transmission DP system.

a direct cooling water circuit in the rear bearing (for exceptionally

cool running in option).

NOTE

: The COBRA BC 0601 G vacuum pumps are principally dispatched

without oil already in the vacuum pump but, without cooling water.

Before vacuum pump first startup, control the oil level and the cooling

liquid level. In the event of absence of one or the other

of these lubricants, please carry out the filling (please refer to the 

various chapters of filling). Do not forget to connect the cooling water 

supply before the first startup. Operation without these coolants can

result in damage to the vacuum pump.

Nitrogen system

The nitrogen system can be used in a number of different ways :

nitrogen is used as dilution gas. It is injected inside the cylinder on

two different places. Nitrogen flow injected in the middle hole is

preset at 2 l/ min and can be adjusted with valve DGR 2, depending

on the application. Nitrogen flow injected in the hole on cylinder

endplate side is preset at 10 l/ min and can be adjusted with valve

DGR 1, depending on the application. When flow is too low a

warning then an alarm signal is generated by flowmeter DGF to the

PLC. Status of the pump depends on the alarm function set by user

(factory setting : None, pump continues running with an alarm).

Dilution improves the screwsfunctioning, especially when sucking

corrosive gases.

nitrogen is used as sealing gas. The nitrogen is injected between the

transmission and the process gas to achieve good closeness. The

Nitrogen flow used for the sealing is set by two chips (

ɸ

). With a

pressure of 1,5 bar, the flow is around 8-10 l/min.

Optional functions/ Use of available

accessories

A pressure sensor (PSA) mounted at the exhaust , controls the 

overpressure at the exhaust. If overpressure is above 0,3 bar, pressure

sensor gives a warning then an alarm signal. Status of the pump 

depends on the alarm function set by user (factory setting : None,

pump continues running with an alarm).
A temperature sensor PT100 (TS 4) mounted on the cylinder, measures

the temperature inside the cylinder (DP).
A silencer or sound absorber (accessory) at the exhaust reduces the 

noise of the pump and collects any condensate.
A leak-protection non-return valve (optional) at the exhaust traps the 

condensate in the pump when the pump is switched off.
The LCD controller processes the data of the sensors as follows:

PSA: exhaust pressure

TS 4: temperature inside the cylinder DP

MOT 1 and MOT 2: DP and MB current and speed

DGF: nitrogen flow rate, dilution

CWM: cooling water flow rate in motors/ transmission/ frequency

inverters

See "Installation and Maintenance Instructions, Busch PLC and BuschLCD (No. 

0870758077)".

On/ Off switch

The vacuum pump is delivered with a circuit breaker. The function start/ stop can

be done in Local by using the LCD controller or in Remote by the production 

machine.

Versions

Further vacuum pump descriptions state the nominal displacement and the 

design level.
Example: BC 0601 G

BC = standard version

601 = 600 m

3

/h

G

= Design

Product description
Page 6

BC 0601 G

0870235875

 (En)

Содержание COBRA BC 0601 G

Страница 1: ...rvice kits Instruction Manual COBRA Screw Vacuum Pumps BC 0601 G 08 12 2020 Busch Manufacturing Korea Ltd 189 51 Soicheon ro Majang myun Icheon si Gyunggi do 467 813 Republic of Korea 0870235875 _en Original instructions Modifications reserved ...

Страница 2: ...e Page 2 0870235875 En Preface worldwide safety transport storage maintenance troubleshooting BC 0601 G 0601G NW 0090 A PUMA WY 0700 D COBRA BC 0601 G 0601 G NW 0090 A WY 0700 D Power connector on vacuum pump rear side ...

Страница 3: ...ns PRV Nitrogen pressure reducer CWC Cooling water connections NC Nitrogen connection CAO Extracting ventilator EB Eye bolts RC LCD PLC PLC box ESS Emergency stop switch EMO OSG Oil sight glass MB On off switch Main circuit breaker RF Ventilator IN EC PRV CWC NC CAO EB RC PLC ESS RF MB BC 0601 G OSG OSG ...

Страница 4: ...l sight glass VFD Variable frequency device MOT1 Motor MOT2 Motor TS Sensor PT100 PS Inlet pressure switch PSA Pressuresensor DGR1 Regulating valve dilution gas DGR2 Regulating valve dilution gas MV Nitrogen solenoid valve DGF Nitrogen flow meter CWM Cooling water flow meter CWRCooling water regulating valve COBRA BC0601G ...

Страница 5: ...le for continuous duty at a pressure more or equal than 150 hPa mbar Caution the operating cycle of 150 hPa mbar must not exceed more than 5 min For other applications contact your Buschrepresentative Maximum inlet pressure 1 bar abs With pump running at full speed do not expose to inlet pressure 300 hPa mbar The vacuum pump istight down to ultimate pressure Operating principle COMBI The COBRA BC ...

Страница 6: ...ng water supply before the first startup Operation without these coolants can result in damage to the vacuum pump Nitrogen system The nitrogen system can be used in a number of different ways nitrogen isused asdilution gas It isinjected inside the cylinder on two different places Nitrogen flow injected in the middle hole is preset at 2 l min and can be adjusted with valve DGR2 depending on the app...

Страница 7: ...t be observed when installing the pump in potentially explosive environments The maintenance instructions must be observed and respected It isvital that these installation and maintenance instructions are read and understood before the vacuum pump isused If you have any doubts please contact your local Buschrepresentative SafetyInformation The vacuum pump has been designed and manufactured in acco...

Страница 8: ...ch off the customer s power supply Switch off the water and nitrogen quick connections inlet first then outlet Put the label or warning board Maintenance processing on or next to the pump Emergencyoff circuitdescription The Emergency off circuit may be opened by pressing on emerge ncy stop button If this element occurs then the DP and MB pumps will immediately stop The PLC will remain energized to...

Страница 9: ...atch Lift the vacuum pump In casethe vacuum pump was bolted to a pallet with fixing bolts Unscrew the fixing bolts in the base frame CAUTION In case of a vacuum pump filled with oil make sure that by lifting the inclination angle of the vacuum pump do not exceed 5 from the horizontal In case of too high inclination 5 risk of oil leak within the work area Make sure before every transport using the ...

Страница 10: ...erpressure 2 5 bar relative Water hardness 5 dGH NOTE 1 german degree 1 dGH 1 78 french degree 1 25 e english degree 17 9 mg kg CaCO3 american hardness Minimum flow rate 3 4 l min for the standard version Make sure that the cooling water is neutral and clean Make sure that the cooling water outlet is unpressurised Make sure that the nitrogen fulfills the following requirements Overpressure 1 5 bar...

Страница 11: ...lines CAUTION When the discharge lines have been connected make sure that the system does not leak Leakages of dangerous substancesmust be prevented Make sure that the discharge line is mounted in such a way that condensate cannot penetrate into the pump siphon trap gradient Make sure that no shut off devices are mounted in the discharge line Make sure that the discharge lines do not exercise any ...

Страница 12: ...vacuum pump is connected correctly before switching it on Determine rotation sense of the motor by using a measure tool or putting a rubber plate on the inlet Press on the start button Make sure that the vacuum pump draws in If not push the Emergency stop button If the direction of rotation has to be changed Exchange two of the three feeder leads Equipment connections with options The information ...

Страница 13: ...ination angle of the vacuum pump do not exceed 5 from the horizontal In caseof too high inclination 5 risk of oil leak within the work area Make sure before every transport using the appropriate lifting mean that the inclination of the vacuum pump is less than 5 CAUTION The vacuum pump must remain in a horizontal position when it has been filled with oil Checking the direct cooling The flow of the...

Страница 14: ...er Drain the cooling water completely If necessary drain the cooling water with the help of compressed air to prevent any risk of frost or corrosion Switchingthe vacuumpump on off First start up of the system Make sure that the Necessary installation instructions are followed If the system isequipped with a solenoid gate valve in the cooling water circuit Open the solenoid gate valve Make sure tha...

Страница 15: ...he colour of the oil see Checking the oil Check the cooling water flow see Checking the cooling water Check the nitrogen flow see Checking the nitrogen Inspect the vacuum pump for oil leaks if there are leaks repair the vacuum pump Busch Inspect the vacuum pump for leaks of cooling water if there are leaks repair the vacuum pump Busch Monthly In the caseof operation in a dusty environment Make sur...

Страница 16: ...nge intervals A drop in the oil level indicates a fault see Alarms and warnings Busch PLC and Busch LCD CAUTION Only fill in oil through the oil filler opening CAUTION Danger of burns when the oil filler cap isopen Danger of injuries when the oil filler cap isnot screwed on properly Only unscrew the oil filler cap when the vacuum pump has been switched off The vacuum pump may only be switched on w...

Страница 17: ... that they do not leak CAUTION Only fill in oil through the oil filler opening Unscrew the oil filler cap OFP Fill in oil up to the middle of the oil sight glass Make sure that the oil level lies between the MIN and MAX markings on the oil sight glasses Make sure that the seals of the filler cap are not damaged and that they sit properly Replace them if necessary Screw on the filler cap again Chec...

Страница 18: ... foreign material Theseforeign materialscaninfiltrate the pores recesses and other internal spacesof the vacuumpump Danger to health duringdismantling of the vacuumpump Danger to the environment During dismantling of the vacuumpumpprotectiveequipmentand clothing mustbe worn Prior to shipping the vacuumpumpmustimperatively be decontaminatedand the degree of contaminationmustbe documentedin a declar...

Страница 19: ...hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check the oil level with the help of the various oil sight glasseson the vacuum pump BC 0601 G Oil type quantity Page 19 0870235875 En Pump type DP pump liters MB pump motor side n 2 liters MB pump gear side n 1 liters BC 0601 G 0 12 l 0 6 l 0 ...

Страница 20: ...ating MB 50 60 Hz kW 1 8 2 2 Electric power capacity at ultimate kW 1 25 pressure Nominal motor speed DP 50 Hz min 1 3000 Nominal motor speed MB 50 60 Hz min 1 3000 3600 Noise level EN ISO 2151 dB A 62 Ambient temperature C F 0 40 32 104 Maximale counter pressure Discharge bar 0 2 Cooling water requirement l min min 3 0 4 0 Cooling water pressure bar τ P 2 5 Nitrogen requirement l min 0 70 Nitroge...

Страница 21: ...cal and electronic equipment and following the standards Person authorised to compile the technical file Gerd Rohweder Busch Dienste GmbH Schauinslandstr 1 DE 79689 Maulburg Icheon si 01 06 2020 Seung hwa Yoo GeneralDirector 1 In case control systems are integrated Standard Title of the standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design ISO 13857 2019 Safety...

Страница 22: ...Note ...

Страница 23: ...Note ...

Страница 24: ...schag ch Belgium info busch be Hungary busch buschvacuum hu Norway post busch no Taiwan service busch com tw Brazil vendas buschdobrasil com br India sales buschindia com Peru info busch com pe Thailand info busch co th Canada info busch ca Ireland sales busch ie Poland busch busch com pl Turkey vakutek ttmail com Chile info busch cl Israel service_sales busch co il Portugal busch busch pt United ...

Отзывы: