Installation | 5
Instruction Manual COBRA BA 0100 C_EN_en
9 | 36
5
Installation
5.1
Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
~50 cm
~20 cm
~20 cm
~20 cm
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the Technical Data.
●
Make sure that the installation space or location is vented such that sufficient cooling of the ma-
chine is provided.
●
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally, a maximum deviation of 1° in any
direction is acceptable.
●
Check the oil level, see Oil Level Inspection [
23].
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level:
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.