7 | Commissioning
20 | 36
Instruction Manual COBRA BA 0100 C_EN_en
7
Commissioning
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
●
Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended periods:
●
Make sure that ear protection is being used.
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
●
Do not lubricate the compression chamber of the machine with oil or grease.
NOTICE
Running without air-cooled system.
Risk of damage to the machine!
●
Make sure that the fan (AF) is running whenever the machine is running.
●
Make sure that the installation conditions (see Installation Conditions [
9]) are met.
If the machine is equipped with a nitrogen system:
●
Turn on the nitrogen supply.
●
Switch on the machine.
●
Make sure that the maximum permissible number of starts does not exceed 6 starts per hour.
Those starts should be spread within the hour.
●
Make sure that the operating conditions comply with the Technical Data.
●
After a few minutes of operation, perform an Oil Level Inspection [
As soon as the machine is operated under normal operating conditions:
●
Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.