5 Operation
Pos: 15 /#Neustruktur#/Online-Dokumentation (+KNX)/Bedienung/Sicherheitstechnik/Busch-Rauchalarm/Bedienung - 6831-6832-84 @ 36\mod_1369206666231_15.docx @ 296205 @ 11112332 @ 1
5.1
Alarm and status signals
Optical signal
Alarm
signal
Meaning Action
Smoke
alarm
Re
d
Flashes fast
Loud
ALARM (local)
Initiate the appropriate safety
and rescue measures.
Flashes once
every 40 seconds
None
The device is ready for
operation
Flashes once
every 40 seconds
Loud.
The device is not ready.
Check the device (battery,
contamination).
Does not flash
None
The device is not ready.
Check the device (battery,
contamination).
Flashes once
every 10 seconds
None
The device has been
switched mute, reduced
sensitivity for 10 minutes
Flashes fast
Loud
Test alarm, test button has
been pressed
5.2
State of the battery
5.2.1 6831-84
When the state of the battery reaches a critical value the device 'bleeps' briefly once every minute for at least 30
days. Replace the battery as soon as possible with a new one.
5.2.2 6832-84
Replace the device as soon as possible.
5.3 False
alarm
If the alarm is triggered for no valid reason, press the test, mute button. This deactivates the warning signal for 10
minutes.