Cable 

 

1.  Install the cable so that it does not vibrate. 
2.  For a standard sensor, do not shorten the cable between the sensor and the 

standardization board. 

3.  Ensure sufficiently large bending radiuses for the cable. 

5.3  Electrical system, evaluation instrumentation 

The output signal from the model 8524 tension and compression load cell, with an excitation voltage of 

10 V, is 15 mV max. Therefore for a measurement accuracy of 0.15% you will need a resolution of 

approx. 10 µV or better. Interference affects the model 8524 tension and compression load cell, cables 

and measurement electronics accordingly. 

The following points apply to the sensor’s electrical connection: 

 

 

NOTICE 

  Position the model 8524 tension and compression load cell outside the 

electromagnet field of high-energy equipment. This includes transformers, motors, 

contactors, frequency converters and so forth. Otherwise the electromagnetic fields 

from such equipment will act with their full effect on the measuring chain, causing 

incorrect measurements. 

  Route the measuring leads separately from power cables. 

  If the measuring leads are laid parallel to power cables, the latter will cause 

inductive and capacitive interference. 

Note: 

You can place an extra screen over the measuring cable for additional protection, or run it 

through a metal tube or pipe. 

5.3.1  Connector pin assignment 

The model 8524 tension and compression load cell is supplied with an open cable end. The model 8524 

tension and compression load cell is optionally fitted with connectors for burster display and calibration 

equipment. 

Note: 

For optionally supplied display and calibration devices, please follow the operating instructions 

for the device to ensure compatibility. 

 

 

NOTICE 

  Relieve the bending stress exerted by the connecting cable on the cable sleeve, at 

the sensor housing. 

  Avoid pulsating or alternating loads on the cable sleeve. 

  Avoid vibrating the cables so that the cable sheath is not damaged. 

  Protect the cables from strain. 

  Protect the model 8524 tension and compression load cell from vapors and liquids. 

  For a standard sensor, do not shorten the cable between the sensor and the 

standardization board. 

Содержание 8524

Страница 1: ...zisionsmesstechnik gmbh co kg burster pr zisionsmesstechnik gmbh co kg All rights reserved Talstr 1 5 Postfach 1432 76593 Gernsbach Germany 76587 Gernsbach Germany Valid from February 09 2021 Tel 49 7...

Страница 2: ...echnik hereinafter referred to as the product are the result of targeted development and meticulous research From the date of delivery burster provides a warranty for the proper condition and function...

Страница 3: ...3of 24...

Страница 4: ...ck 9 2 6 Unpacking 9 2 7 Warranty 9 2 8 Maintenance 9 2 8 1 Recalibration 9 2 9 Conversions and modifications 10 3 Concept and general information 11 3 1 Mechanical design 11 3 2 Principle of operatio...

Страница 5: ...on 8524 xxxx xxExxxxx 19 5 3 1 4 Option 8524 xxxx xxFxxxxx 20 5 3 1 5 Option 8524 xxxx xxHxxxxx 20 6 Measurement chain calibration 21 7 Technical data 22 7 1 Electromagnetic compatibility 22 7 1 1 Int...

Страница 6: ...gree of risk indicates a hazardous situation which if not avoided may result in death or serious injury CAUTION Low degree of risk indicates a hazardous situation which if not avoided could result in...

Страница 7: ...You will find the serial number on the type plate of the model 8524 tension and compression load cell 2 1 2 Contact person If you have any questions relating to the model 8524 tension and compression...

Страница 8: ...outputs or other devices that are galvanically connected to the sensor s signal lines must also be fitted with safety transformers to EN 61558 2 3 3 Restrictions on use The model 8524 tension and comp...

Страница 9: ...ssion load cell should be shipped only in its original packaging or in packaging capable of providing an equivalent degree of protection 2 7 Warranty burster pr zisionsmesstechnik gmbh co kg provides...

Страница 10: ...ny parts that are intended to be serviced by the user Only the manufacturer s own qualified personnel are permitted to open the model 8524 tension and compression load cell It is not permitted to make...

Страница 11: ...nto an electrical signal The strain gages and spring element together constitute the measuring element 3 2 1 Spring element The spring element is the most important mechanical part of a load cell Its...

Страница 12: ...or the model 8524 tension and compression load cell It is typically in the region of 1 5 mV V 0 25 In conjunction with the reference excitation voltage Ub in a range of max 10 V we recommend 5 V signa...

Страница 13: ...8524 tension and compression load cell Absolutely avoid any load that applies a sudden force impulse Note The high spring constant of the model 8524 tension and compression load cell results in high...

Страница 14: ...re fitted with a safety transformer to EN 61558 Note Transmitters connected to the outputs or other devices that are galvanically connected to the signal lines of the model 8524 tension and compressio...

Страница 15: ...orce 1 Apply the force being measured to the model 8524 tension and compression load cell via the central thread 2 Apply the force centrically exactly along the axis of symmetry IMPORTANT Eliminate an...

Страница 16: ...ion if the model 8524 tension and compression load cell is used as a weighing device on containers 5 2 Fixing method The entire contact surface of the model 8524 tension and compression load cell must...

Страница 17: ...uring chain causing incorrect measurements Route the measuring leads separately from power cables If the measuring leads are laid parallel to power cables the latter will cause inductive and capacitiv...

Страница 18: ...tion for Figure 7 Only with extended cable over 5 m in length Optional 5 3 1 1 Option 8524 xxxx xxBxxxxx Connection to burster devices with 9 pin D sub socket with 6 wire system IMPORTANT The tension...

Страница 19: ...r TEDS Figure 10 Device connection Figure 11 Connection to 9 pin burster TEDS 5 3 1 3 Option 8524 xxxx xxExxxxx Connection to burster devices with 9 pin D sub socket with 4 wire system for 9163 V3xxx...

Страница 20: ...to burster devices with 12 pin round connector Figure 14 Device connection Figure 15 12 pin round connector pin assignment 5 3 1 5 Option 8524 xxxx xxHxxxxx Connection with 8 pin connector Figure 16...

Страница 21: ...can also download this test and calibration certificate at a later date by entering the serial number on the burster website www burster com The downstream electronics must always be calibrated for t...

Страница 22: ...s tension and compression load cells p detail 8524 or simply use the following QR code Figure 18 Technical data QR code 7 1 Electromagnetic compatibility 7 1 1 Interference immunity Interference immun...

Страница 23: ...ta sheet for details of the accessories available The latest version of the data sheet is available at https www burster de en sensors load cells tension and compression load cells p detail 8524 or si...

Страница 24: ...disposal If your instrument is no longer usable please comply with your legal obligations by disposing of the instrument described here in accordance with statutory regulations You will then be helpi...

Отзывы: