68
Electrical installation
Type 8098 FLOWave L
8.15
Wiring output 2 (digital) and output 3 configured as a
digital output (device variant with cable glands)
NOTICE
Risk of short-circuit if the configuration of output 3 is wrong.
▶
Before wiring output 3 as a digital output, make sure output 3 is configured as a digital output in the
Parameter menu of the outputs. See chapter 18.2 Changing the type of output 3
A digital output can be wired either in NPN mode or in PNP mode.
1
1 2 3 4 5 6 7 8 9 1 1 2
1
0
+
-
+
-
12-35 V DC
+
-
12-35 V DC
+
-
Load connected
to output 3
Load connected
to output 2
Power supply for
output 3
Power supply for
output 2
Orange LED is lit if the
related digital output is
switched to ON
Fig. 34:
Wiring the digital outputs
English
Содержание Flowave 8098
Страница 1: ...Operating Instructions Type 8098 FLOWave L SAW Flowmeter Software version A 04 00 00 and higher...
Страница 4: ...General contents 4 Type 8098 FLOWave L English...
Страница 12: ...12 Type 8098 FLOWave L English...
Страница 36: ...36 Technical data Type 8098 FLOWave L English...
Страница 72: ...72 Type 8098 FLOWave L English...
Страница 78: ...78 Commissioning Type 8098 FLOWave L English...
Страница 96: ...96 Type 8098 FLOWave L English...
Страница 144: ...144 Type 8098 FLOWave L English...
Страница 248: ...248 Type 8098 FLOWave L English...
Страница 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Страница 304: ...304 Type 8098 FLOWave L English...
Страница 316: ...316 Type 8098 FLOWave L English...
Страница 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Страница 352: ...352 Appendix Type 8098 FLOWave L English...
Страница 353: ......
Страница 354: ...www burkert com...