74
Start-up
→
Start
X.TUNE
by pressing key 1 for 5 s
26)
.
LED 2 flashes at 5 Hz. The device is in NAMUR state functional inspection, LED1 lights orange.
If X.TUNE has been successfully complete, the NAMUR state is reset. The changes are automatically
adopted in the memory (EEPROM).
If LED1 lights red after X.TUNE:
→
Execute X.TUNE again.
→
Perform device restart if necessary.
16.3
Set device with Bürkert Communicator
All settings can be made on the device with Bürkert Communicator.
You can find the settings in Bürkert Communicator in the operating instructions.
16.3.1
Connecting the IO-Link device to the Bürkert Communicator
Necessary components:
•
Communication software: Bürkert Communicator for PC
•
USB büS interface set (see accessories)
•
büS adapter for communication interface (see accessories)
•
A büS cable extension if necessary (see accessories)
→
To connect the IO-Link device to Bürkert Communicator, unscrew the housing cover.
LED 1
LED 2
Key 1
Key 2
DIP switch
Communication
interface
Fig. 38:
Description of operating elements
26) X.TUNE can also be started via communication software.