Type 8756
Technical data
english
18
Fluid connections
Seal material
Operating
pressure
▪
Fluid connections with ex-
ternal-threaded vacuum fit-
tings
▪
Fluid connections with ex-
ternal-threaded compression
fittings
▪
metal
▪
FFKM
▪
PCTFE
max. 50 bar
Tab. 3: Maximum operating pressure
4.2.2
Mass Flow Controller with pump
Ambient temperat-
ure
0 °C...+50 °C
Fluid temperature –10 °C...+60 °C, only in liquid state
Ambient humidity
< 95%, non-condensing
IP-Code according
to EN 60529
IP40
5
If the following conditions are met:
▪
Cables must be connected.
▪
Mating connectors must be plugged in and
tightened.
Operating pressure
▪
Inlet pressure
▪
0 bar
▪
Outlet pressure
▪
max. 10 bar
Tab. 4: Operating conditions of an MFC with pump
4.2.3
Mass Flow Controller with proportional
valve
Ambient temperat-
ure
0 °C...+50 °C
Fluid temperature –10 °C...+60 °C, only in liquid state
Ambient humidity
< 95%, non-condensing
IP-Code according
to EN 60529
IP65
6
If the following conditions are met:
▪
Cables must be connected.
▪
Mating connectors must be plugged in and
tightened.
Operating pressure
▪
Inlet pressure
▪
max. 5 bar
Tab. 5: Operating conditions of an MFC with proportional valve
4.2.4
Mass Flow Controller for modular
actuator
Ambient temperat-
ure
0 °C...+50 °C
Fluid temperature –10 °C...+70 °C, only in liquid state
5
The IP-Code is determined by Bürkert. The IP-Code is not evaluated by UL.
6
The IP-Code is determined by Bürkert. The IP-Code is not evaluated by UL.