30
Technical data
Type 8745 Ethernet, 8745 Analogue
6.8.2
Operating gas is not air
If the operating gas is not air, determine the pressure loss as
follows:
1.
Read the air pressure-loss p
air
from the diagrams in Fig. 13
2.
Calculate the pressure loss p
gas
with the formula that is
ρ
ρ
air
air
= pressure loss of the operating gas
air
= pressure loss of air
ρ
= density of the operating gas at the standard con
-
ditions according to DIN 1343 (P
N
= 1013.25 mbar,
T
N
= 273.15 K)
ρ
air
= density of air at the standard conditions according to
DIN 1343 (P
N
= 1013.25 mbar, T
N
= 273.15 K)
Fig. 15: Formula to calculate the pressure loss in an MFM
Example for argon gas that flows through an MFM with 1/2"
threaded fluid-connections:
1.
If the flow rate is 1400 l
N
/min then the air pressure-loss p
air
2.
The pressure loss for argon gas at a flow rate of 1400 l
N
/min
is 164.4 mbar as given by the calculation in
argon
= 140 mbar
1.784
1.294
= 164.4 mbar