background image

TSE HOME 4001

English |

 

11 

Remark

The basic size of the cylinder is 30 mm for each side. When delivered,  
the cylinder is completely pushed together (smallest possible cylinder length). 
Before you embed the cylinder into the door, you need to adjust the exterior 
knob to door thickness.

To install the cylinder, proceed as follows:
1

  Take a rough measurement of the door thickness (incl. fittings)

2

   Pull the inner knob away from the shaft, move the outer knob over the 

detent system (spacing 2.85 mm) to the required dimension. 

 
 
 
 

Schematic representation of 
adjustment of the outer knob

3

   the TSE cylinder outside in through the mortise lock into  

the door and then tighten the fixing screw.

 

 
 
 
 
 
 
 

4

   Shift the outer knob along the shaft until the required dimension is 

attained. Please make sure that the distance between the rotary knob  
and the door mounting is at least 1 mm. Then fix the knob using the  
hex key.

5

   Shift the interior knob into the required position on the shaft and fix  

it with a distance of at least 1 mm from the strike plate by using the  
hex bolt. 
 
Make sure that the interior knob is shifted on the shaft in a way that  
the fixing screw (inside the knob) faces the shaft with the little holes  
at the side. 
 
 
 
 
 

6

   The function test must be made while the door is open. 

Replacing the knob batteries (exterior)

Attention: When replacing the batteries, make sure that no 
precipitations or humidity penetrate the batteries, as no water can 
escape when the compartment has been closed. 

1

   Loosen the hex screw on the cover and remove it. 

The fixing  

screw may be loosened only so far that the cover can be  
opened. It must never be unscrewed from the cover.

 

 
 
 
 
 

2

   Pull the silicone cover out and replace the batteries.  

Check the correct polarity of the cells. 
 
 
 
 
 
 

3

   Place the silicone cover on the batteries, close the cover  

and tighten the fixing screw. 
 
 
 
 
 
 

Содержание TSE 4001

Страница 1: ... 15 58300 Wetter Germany Elektronisches Türschloss BA MA TSE Set 4001 dp mri dn 11 2011 Montage und Bedienungsanleitung Installation and User Manual Instruction de montage et mode d emploi Montage en gebruiksaanwijzing HOME Genial sicher Genial einfach ...

Страница 2: ... In most cases this is a sign of low batteries in the keypad or in the cylinder Please replace the batteries immediately I Key confirmation Any successful key operation is confirmed with a brief flashing of the green central confirmation LED Structure Dear customer thank you very much for choosing the BURG WÄCHTER TSE 4001 electronic locking system This system has been developed and manufactured u...

Страница 3: ...dministrator code Factory setting 123456 you absolutely need to change this In the following description the administrator code is referred to as pincode 1 Commissioning When the TSE 4001 pincode is first put into operation it is necessary to perform a certain procedure as the system is delivered from the factory in a special power saving mode Press On the green ready for opening icon flashes brie...

Страница 4: ...nels Enter the programming mode using the current opening code Type 72X X indicates the radio channel numbers 1 to 12 also 01 etc are allowed then press the Enter key The combination 72 stands for RC RF channel When the action has been performed successfully the green ready for opening LED goes on while the red entry denied one goes on in case of error 8 Registering the keypad Press On type in 82 ...

Страница 5: ...ut a function test of the unit while the door is open In order to do so enter the valid pincode several times Installation instructions for TSE cylinder The installation of the TSE cylinder is described below Please read this Manual carefully before the assembly and then store it at a safe place The cylinder is provided with a special detent system offering you a possibility of using the cylinder ...

Страница 6: ...ry knob and the door mounting is at least 1 mm Then fix the knob using the hex key 5 Shift the interior knob into the required position on the shaft and fix it with a distance of at least 1 mm from the strike plate by using the hex bolt Make sure that the interior knob is shifted on the shaft in a way that the fixing screw inside the knob faces the shaft with the little holes at the side 6 The fun...

Отзывы: