Changing Water Filter (Filtered models only). 

The boiler will alert when a new filter cartridge is required. The boiler should be descaled in conjunction with 
the filer change, see page 14 of instructions. 

 

 

 

 

The water filter cartridge is unique to Burco. Only Burco “BC02” replacement filter (Part No. 01/74334/0) 

will  fit  these  models.  Please  either  purchase  a  replacement  from  your  catering  equipment  supplier,  or 

alternative order replacements via: 

 

 

0344 879 3470   

 www.burco.co.uk

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 

 

   Failure to use the correct filter cartridge will affect performance and invalidate the boilers warranty. 

 
Cleaning Instructions

 

 

It is recommend that your water boiler is cleaned on a regular basis. Failure to do so may result in 

the appliance not operating to its full potential and may invalidate your warranty. 

 

   Disconnect from the electrical supply before cleaning and allow water boiler to cool.

 

Do not immerse the water boiler in water or any other liquids and take care to keep water away from 
the supply cord and connections. Do not use a water jet or steam cleaner. 

 

External Cleaning 

Wipe the external surfaces & dispensing tap of the appliance with a damp cloth. It is recommended that this is 
done daily to prevent lime scale build up. Stubborn stains may be removed using a good stainless steel cleaner 
or non-abrasive cleaner. Hard to reach areas should be cleaned using a soft brush & mild cleaning solution. 
 

Failure to clean on a regular basis may invalidate your warranty.

 

1.

 

Locate the filter below 

the boiler. 

2.

 

Twist cartridge anticlockwise & remove. 

(residual water may be present) 

2.

 

 

3.

 

Remove all film and packing, 

insert new filter cartridge.   

1.

 

 

4.

 

Twist the cartridge clockwise 
until locked in position.  

5.

 

To reset filter timer, PRESS & HOLD the UP 
& DOWN buttons until you hear a beep. 

Содержание 069801

Страница 1: ...ilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Aftersales Tel 0344 879 3470 www burco co uk Please keep these instructions in a safe place 08 54071 0 Jan 19 These instructions cov...

Страница 2: ...hooting 15 Spare Replacement Part information 15 Frequently asked questions FAQ s 16 About my product Please take some time to complete the information below it may save time if you need to contact us...

Страница 3: ...EGULATIONS BS CODES OF PRACTICE LOCAL AND NATIONAL BUILDING REGULATIONS LOCAL AND NATIONAL WATER REGULATIONS THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED...

Страница 4: ...O ACTS AS A VENT FOR THE APPLIANCE UNDER NO CIRCUMSTANCES SHOULD THIS FLEXIBLE HOSE BECOME BLOCKED OR RESTRICTED IN ANY WAY THIS APPLIANCE MUST ONLY BE USED FOR HEATING WATER THE UNIT MUST BE INSTALLE...

Страница 5: ...ter boiler please contact our Aftersales team on 0344 879 3470 To ensure we can offer you the best possible service please ensure you have the product code and serial number available from page 2 Your...

Страница 6: ...rick wall by a qualified fitter Burco does not accept any responsibility for the safety of any unit not installed in this way 1 Mark the position of the 2 mounting holes 300mm apart as shown in the di...

Страница 7: ...ins supply Always ensure mains water supply is turned off or localised isolation valves are closed before attempting to connect boiler to the mains water supply The inlet water connection to the inlet...

Страница 8: ...ible wires up to 6mm Overflow and Drainage As an option the boiler overflow outlet may be connected to a drainage system There may be some steam emitted from the vent at the base of the appliance duri...

Страница 9: ...sonnel to the appropriate standards Appliance not available with a standard 13Amp UK 3 pin plug Controller Overview Before general use please follow these important commissioning steps Ensure boiler i...

Страница 10: ...to deactivate the screen lock function If in locked mode the lock logo will blink on the screen for a couple of seconds if any button is pressed Set Time Press MENU SET CLOCK will be highlighted Press...

Страница 11: ...y When no water is drawn from the boiler in 2 hours the eco mode is engaged The backlight turns off and the only data displayed is the Burco logo along with the time and the status indicator Water sho...

Страница 12: ...unter reset refer to replacement parts Power Down To power down the product the STANDBY button should be held when on the normal operation screen for 10 seconds The shutdown screen will appear and usi...

Страница 13: ...d allow to cool down 9 Remove the tank cap again to inspect the tank and level detectors for scale deposits 10 Drain and flush the de scaling agent from the tank using tap on the front of theappliance...

Страница 14: ...rranty Disconnect from the electrical supply before cleaning and allow water boiler to cool Do not immerse the water boiler in water or any other liquids and take care to keep water away from the supp...

Страница 15: ...screen can be scanned using an iPhone Android and Windows device which will take you to the Burco website Spare Replacement Parts Genuine replacement Burco parts must be fitted If generic non Burco p...

Страница 16: ...a Replace filter and reset the filter counter If you need further help see the demonstration video on our website at www burco co uk changefilter 5 The water from the tap is cold a Check appliance is...

Отзывы: