  Before connecting to the power supply 

  Remove all packaging and plastic coating from the appliance  

  Check the unit has not been damaged in any way during transportation. Report any damage to the 

company who sold you the boiler right away. 

  Check the available power supply corresponds to that shown on the rating label of the appliance, which 

must be A.C. (Alternating Current). 

  Ensure the yellow steam cap is removed from the steam vent prior to powering appliance. 

Connecting to the water supply 

  Connection to the cold water supply and the appliance should only be made by the hose supplied. 

  In hard water areas, it is always advisable to fit an inline filtration unit to limit scale build-up. If you have 

purchased a Burco boiler that does not have a water filter system included, we recommend you fit a 
separate water filter between the boiler and the mains supply. 

  Always  ensure  mains  water  supply  is  turned  off,  or  localised  isolation  valves  are  closed  before 

attempting to connect boiler to the mains water supply. 

  The inlet water connection to the inlet solenoid valve is 

¾” BSP, this should be connected to the mains 

water supply via an accessible isolating tap. 
 
 
 
 
 
 
 
 
 
 
 

  The blue pipe at the bottom of the boiler connects to the grey fitting which is shown in picture 1 above.  

  Firmly push the blue pipe into the small outlet hole on the grey fitting. 

  Ensure grey connection is screwed tight  on the mains water supply and not leaking, forming a cold 

water feed from the mains water supply to the Burco boiler. 

  Do not use old water hoses.  

 Venting 

  There is a possibility the steam vent may discharge hot or cold water and/or steam into the local vicinity 

of the boiler. If uncontrolled, steam or water damage may occur in this area. It is recommended that 
the vent on the base of the boiler is plumbed to a safe visible location.   

  Please ensure that any building and/or water regulations are fully adhered to. 

 

STEAM VENT 

1. 

2. 

Содержание 069801

Страница 1: ...ilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Aftersales Tel 0344 879 3470 www burco co uk Please keep these instructions in a safe place 08 54071 0 Jan 19 These instructions cov...

Страница 2: ...hooting 15 Spare Replacement Part information 15 Frequently asked questions FAQ s 16 About my product Please take some time to complete the information below it may save time if you need to contact us...

Страница 3: ...EGULATIONS BS CODES OF PRACTICE LOCAL AND NATIONAL BUILDING REGULATIONS LOCAL AND NATIONAL WATER REGULATIONS THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED...

Страница 4: ...O ACTS AS A VENT FOR THE APPLIANCE UNDER NO CIRCUMSTANCES SHOULD THIS FLEXIBLE HOSE BECOME BLOCKED OR RESTRICTED IN ANY WAY THIS APPLIANCE MUST ONLY BE USED FOR HEATING WATER THE UNIT MUST BE INSTALLE...

Страница 5: ...ter boiler please contact our Aftersales team on 0344 879 3470 To ensure we can offer you the best possible service please ensure you have the product code and serial number available from page 2 Your...

Страница 6: ...rick wall by a qualified fitter Burco does not accept any responsibility for the safety of any unit not installed in this way 1 Mark the position of the 2 mounting holes 300mm apart as shown in the di...

Страница 7: ...ins supply Always ensure mains water supply is turned off or localised isolation valves are closed before attempting to connect boiler to the mains water supply The inlet water connection to the inlet...

Страница 8: ...ible wires up to 6mm Overflow and Drainage As an option the boiler overflow outlet may be connected to a drainage system There may be some steam emitted from the vent at the base of the appliance duri...

Страница 9: ...sonnel to the appropriate standards Appliance not available with a standard 13Amp UK 3 pin plug Controller Overview Before general use please follow these important commissioning steps Ensure boiler i...

Страница 10: ...to deactivate the screen lock function If in locked mode the lock logo will blink on the screen for a couple of seconds if any button is pressed Set Time Press MENU SET CLOCK will be highlighted Press...

Страница 11: ...y When no water is drawn from the boiler in 2 hours the eco mode is engaged The backlight turns off and the only data displayed is the Burco logo along with the time and the status indicator Water sho...

Страница 12: ...unter reset refer to replacement parts Power Down To power down the product the STANDBY button should be held when on the normal operation screen for 10 seconds The shutdown screen will appear and usi...

Страница 13: ...d allow to cool down 9 Remove the tank cap again to inspect the tank and level detectors for scale deposits 10 Drain and flush the de scaling agent from the tank using tap on the front of theappliance...

Страница 14: ...rranty Disconnect from the electrical supply before cleaning and allow water boiler to cool Do not immerse the water boiler in water or any other liquids and take care to keep water away from the supp...

Страница 15: ...screen can be scanned using an iPhone Android and Windows device which will take you to the Burco website Spare Replacement Parts Genuine replacement Burco parts must be fitted If generic non Burco p...

Страница 16: ...a Replace filter and reset the filter counter If you need further help see the demonstration video on our website at www burco co uk changefilter 5 The water from the tap is cold a Check appliance is...