LOWLANDER MK4 MANURE SPREADER – INSTRUCTION & SPARES MANUAL
Page
22
You will be testing one cell at a time, so make sure the other loadcell wires are not
connected/touching the input or this will affect the results.
•
Connect 1 loadcell in the weighing module
•
Zero the weight reading in “Weight Setup – Tare Calibration”:
•
Go into the loadcell diagnostics page (Diagnostics – LCI Diagnostics) and note down the
voltage/weight readings. The voltage should remain stable, with only a small fluctuation of the
last decimal point and the weight reading should remain at/very close to zero.
A normal zero reading will be around 0.1-0.7v anything above or below this could indicate an
issue.