Page 21
SERVICE (cont.)
ON/OFF SWITCH
FIG. 12 ON/OFF SWITCH
P2150.40
Location:
The ON/OFF switch is located in the front of the
hood, above and to the right of the brew funnel.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Remove the black and white/red wires from the
switch terminals.
3. With a voltmeter, check the voltage across the
black wire removed from the ON/OFF switch and
the white wire remaining on the switch terminal.
4. Connect the brewer to the power source. The in-
dication must be 120 volts ac.
5. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the
Wir-
ing Diagram and check the wiring harness.
6. Check for continuity across the center and end
terminals of the bottom row when the switch is in
the “ON” position.
If continuity is present as described, replace the wires,
the switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress the clips inside the hood and gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold the switch captive in the hood.
4. Refer to FIG. 13 when reconnecting the wires.
FIG.13 ON/OFF SWITCH TERMINALS
P2144
BLK to Control
Board J1-7
WHI to Power Cord
33030 052600
WHI/RED to On/Off
Switch
WHI/RED to Control
Board J1-8
WHI/RED to On/
Off Switch