Page 19
DISCONNECT BREWER
FROM WATER SUPPLY
BEFORE DRAINING
CALIBRATE FLOW ?
NO YES
C
CAL TEMPERATURE
Use of this test allows user to "tell" the brew exactly how
many ounces are collected during a 10 second test mode.
BREWING
DO NOT OPEN!!!!
There will be several warning & informational screens dur-
ing this test mode.
DO NOT OPEN BREW CHAMBER OR REMOVE CONTAINER
UNTIL FINISHED.
Entire process (including press out) takes approximately
2 - 2½ minutes.
(4)
(5)
HOT LIQUIDS!!!!
HOT LIQUIDS!!!!
ENTER OZ 10.0
(6)
(-)
(+)
DONE
When the test finishes, use the +/- buttons to enter the
amount of water captured in the measuring container.
Press "DONE" when finished.
FlowCounts/ 10oz
(7)
352
This screen shows the calculation of flow meter pulses
based on aproximately 10 ounces.
D
NO SENSOR? YES
Temperature probe calibration should only be used by
authorized service technicians when replacing the CBA or
temperature probe. Refer to service manual.
FACTORY BLOWOUT
WARNING: ALLOW TANK TO COOL FIRST. USE THIS MODE
FOR TANK DRAINING ONLY. HAVE DRAIN HOSE IN SINK
OR CONTAINER BEFORE PRESSING "YES".
E
NO SENSOR? YES
42822.1 072810
ADVANCED ADJUSTMENTS & OPTIONAL SETTINGS