Page 18
1 2 3 4
OFF
ON
FIG 18B
SWITCH SETTINGS
Program Switches:
1. Unplug the brewer and let it cool down before proceeding.
3. Remove the left rear cover.
4. Flip the dip switches as needed.
NOTE: All switches are turned OFF from factory.
FIG 18A
KEY #
FUNCTION - OFF
FUNCTION - ON
4. High altitude
Set temp 200°F (93°C)
Set temp 190°F (87.8°C)
3. Energy Save
No energy save mode
Drops to 140°F (60°C) @ 6 hours/OFF @ 26h
2. Brew lockout
Brew @ any temp
Only brews when it indicates ready
1. Program lockout
Programming allowed
All programming locked out
40410 092407