(A) ENABLE BREW ON/OFF SWITCH

Pressing the "ENABLE BREW ON/OFF" switch (indicator/display on) enables the brew circuit, and the tank refill 

circuit. Pressing the switch again (indicator/display off) stops tank refilling and brewing. Stopping a brew cycle 

after it has been started will not stop the flow of water into the server until the funnel is empty.

NOTE 1: – Stopping a brew cycle by pressing the "ENABLE BREW ON/OFF" switch to the "OFF" position, will dis-

able the tank refill circuit. If the level is low enough, tank heating may be disabled as well. Simply pressing the 

"ENABLE BREW ON/OFF" switch to the "ON" position will allow the tank to replenish. Allow a few minutes for the 

tank to heat back up to it's ready temperature.

NOTE 2: – Hot water will be available at the faucet in a limited amount when the "ENABLE BREW ON/OFF" switch 

is in the "OFF" position because the tank will not refill. Refer to NOTE 1 regarding low level.

(B) BREW A SWITCH (-)

Momentarily pressing and releasing the switch starts the selected "A" brew cycle when the "ENABLE BREW ON/

OFF" indicator is on. (Factory set for approx. 64 ounces) (Coffee brewing on combo models)

(C) BREW B SWITCH (+)

Momentarily pressing and releasing the switch starts the selected "B" brew cycle when the "ENABLE BREW ON/

OFF" indicator is on. (Factory set for approx. 64 ounces) (Tea brewing on combo models)

(D) HIDDEN PROGRAM SWITCH (Enter)

(E) STATUS DISPLAY

Indicates tank ready, brew cycle, and drip out cycle.

(F) BATCH SIZE/FLAVOR LABELS

Included

OPERATING CONTROLS - SMART WAVE WITH DISPLAY

E

FIG 11

Smart Wave Series

D

40410  013014

F

Содержание Smart Wave Series

Страница 1: ...he latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE a...

Страница 2: ...atements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the war...

Страница 3: ...ice personnel only Disconnect power before servicing To reduce the risk of electric shock do not remove or open cover No user serviceable parts inside Authorized service personnel only Disconnect powe...

Страница 4: ...ctrical service as specified in conformance with all local and national codes This appliance must not be cleaned by water jet This appliance is not intended for use by persons including children with...

Страница 5: ...le valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow NOTE If a backflow preventer is required by code a shock arrestor s...

Страница 6: ...EW ON OFF switch Indicator Display must be lit Water will flow into the tank and stop when the tank is filled to its capacity 5 Wait approximately twenty minutes for the water in the tank to heat to t...

Страница 7: ...ce an empty server customer supplied under the funnel 6 Verify that the ENABLE BREW ON OFF switch is on 7 Momentarily press and release the desired BREW switch The display will read BREWING flashing r...

Страница 8: ...until it stops 5 Place an empty server customer supplied under the funnel FIG 8B 6 Verify that the ENABLE BREW ON OFF switch is on 7 Momentarily press and release the BREW B switch The display will r...

Страница 9: ...tion will allow the tank to replenish Allow a few minutes for the tank to heat back up to it s ready temperature NOTE 2 Hot water will be available at the faucet in a limited amount when the ENABLE BR...

Страница 10: ...nce approximate of water to be removed from the existing setting Press and hold the small BREW switch until you hear the solenoid click on and off three times approximately 10 seconds then release the...

Страница 11: ...the tank to heat back up to it s ready temperature NOTE 2 Hot water will be available at the faucet in a limited amount when the ENABLE BREW ON OFF switch is in the OFF position because the tank will...

Страница 12: ...e middle bars on the display will be on After 10 Seconds the the 3 upper middle and lower bars on the display will be lit for 5 seconds During that 5 seconds release and again press the ENABLE BREW ON...

Страница 13: ...he display will then change to 1 14 Brewer has 14 preset pulse brew routines to choose from Factory default is 1 With 14 being the maximum time Press BREW A to decrease or BREW B to increase 6 Press a...

Страница 14: ...e sprayhead by turning it to the left with your fingertips and set it aside 4 With the sprayhead removed insert the deliming spring pro vided all the way into the sprayhead tube When inserted properly...

Страница 15: ...ove the sprayhead by turning it counterclockwise with your fingertips 3 Disassemble sprayhead by removing rubber gasket 4 Check the holes in the sprayhead If plugged by lime they may be cleared using...

Страница 16: ...e the brew funnel 2 Remove upper and lower screws on either side of front cover 3 Loosen middle screw on either side of front cover 4 Pull front cover towards front of brewer Top Cover 1 Remove both s...

Страница 17: ...proceeding 2 Remove the brew funnel 3 Remove the front cover 4 Pinch fill hose 5 Loosen clamp from fill solenoid 6 Remove hose from solenoid and drain into sink as shown or 2 gallon bucket 7 After dr...

Страница 18: ...itches as needed NOTE All switches are turned OFF from factory FIG 18A KEY FUNCTION OFF FUNCTION ON 4 High altitude Set temp 200 F 93 C Set temp 190 F 87 8 C 3 Energy Save No energy save mode Drops to...

Страница 19: ...R OPEN CALL SERVICE 3 ER 3 HEATING TOO LONG CALL SERVICE 4 ER 4 REFILL TOO LONG CHECK WATER SUPPLY 5 ER 5 HIGH TANK LEVEL DURING BREW DELIME 6 ER 6 CHECK ENABLE BREW ON OFF SWITCH CHECK SWITCH 7 ER 7...

Страница 20: ...N ON 0 OFF ORN 12 ORN GRN TAN WHI ORN 12 WHI PNK RED BLK ON 0 OFF GRN YEL WHI RED RED LEVEL PROBE DISPLAY BOARD t J3 1 BLK 5V HOT 4 5V COLD BLU L1 N AIR PUMP MOTOR 12VDC WATER INLET SOLENOID 1 BRN ORN...

Страница 21: ...K BLK 14 RED BLK RED WHI WHI BLK J2 1 J5 1 BRN ON 0 OFF ORN 12 ORN GRN TAN WHI ORN 12 WHI PNK RED BLK ON 0 OFF GRN YEL WHI RED RED LEVEL PROBE DISPLAY BOARD t J3 1 BLK 5V HOT 4 5V COLD BLU AIR PUMP MO...

Страница 22: ...N 0 OFF ORN 12 ORN GRN TAN WHI ORN 12 BLK PNK RED BLK ON 0 OFF GRN YEL WHI RED RED LEVEL PROBE DISPLAY BOARD t J3 1 WHI 5V HOT 4 5V COLD BLU L1 N AIR PUMP MOTOR 12VDC WATER INLET SOLENOID 1 BRN ORN 12...

Страница 23: ...BLK WHI WHI WHI BLK J2 1 J5 1 BRN ON 0 OFF ORN 12 ORN GRN TAN WHI ORN 12 BLK PNK RED BLK ON 0 OFF GRN YEL WHI RED RED LEVEL PROBE DISPLAY BOARD t J3 1 WHI 5V HOT 4 5V COLD BLU L1 N AIR PUMP MOTOR 12VD...

Отзывы: