Page 15
PROGRAMMING (cont.)
MODIFYING RECIPES
By default, recipe settings are preset from the factory. The operator has the choice of enabling, disabling
and modifying any recipe setting.
HOW TO ACCESS RECIPE SETTINGS
1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS.
2. Select the ADVANCED icon.
3. At the PASSWORD ENTRY screen, select ENTER (If a password is required, enter the code at this screen).
4. In the SERVICE MENU screen, select the RECIPE icon.
5. The RECIPE EDIT screen will appear on the display. If necessary, use the scroll arrow at the top of the screen
to navigate to the desired recipe name to edit. Select the recipe name.
6. Enable the batch size you wish to modify by selecting the white checkbox. If the batch size is already enabled
as indicated by the green checkmark, proceed to the next step.
7. Select the batch icon next to the size you wish to modify (small, medium and large).
8. The screen that will appear has a menu of icons that represent settings you can enable, disable or modify.
VOLUME - This icon allows for volume adjustments. Each batch size, small, medium, and large will
have adjustable brew volume ranges to choose from. Pressing SAVE after the number has been
entered will confirm the change and exit back out to the recipe parameter screen.
BYPASS (ITCB HV Only)- This icon adjusts the bypass as a percentage of the total brew volume.
This means the set percentage will bypass the coffee grounds through the funnel to the server. If
bypass is used in a recipe, it will only turn on after 30 seconds of sprayhead time. The operator will
press SAVE to confirm their entry, which will exit them back to the recipe parameter screen.
DILUTION - Dilution is used in tea brewing to dilute the concentrate of tea brewed in the funnel.
The user will set the amount desired in ounces or ml. The user can adjust the volume by touching
the text field and prompting the numeric keypad or use the plus or minus butttons to increment or
decrement the volume. Save confirms the change and exits the user back to the recipe parameters
screen. The arrow will just take user back to the recipe parameter screen.
DILUTION DELAY - This feature allows the user to set a time when the dilution water should turn
on after a brew cycle has been initiated. The user can adjust the time by touching the text field and
prompting the numeric keypad or use the plus or minus butttons to increment or decrement the
time. Save confirms the change and exits the user back to the recipe parameters screen. The arrow
will just take user back to the recipe parameter screen.
RECIPE
EDIT
VOLUME
SMARTWAVE
RECIPE REVIEW
PULSE BREW
PRE-INFUSE
FRESHNESS
DRIP TIME
DILUTION
DILUTION DELAY
BYPASS
55502
000000
Содержание ITCB DV