4

OPERATING CONTROLS

Off/On/Start Switch

OFF - (upper position) Switching to this position stops all operation of the grinder.

ON - (middle position) The switch will return to this position after a grind cycle has begun and will remain 

in this position after grinding has ceased.

START - (lower, momentary position) Pressing the switch initiates a timed grind cycle.

Hopper Selector Switch

 

Left - Switching to this position allows beans to be dispensed from the 

left hopper.

 

Right - Switching to this position allows beans to be dispensed from the 

right hopper.

Dispense Timer

 

The dispense timer controls the amount of beans that will leave the hopper in a grind cycle. The timer can 

be adjusted to dispense a different amount from each hopper. The scale is from 0.4 to 150.0 seconds.  Refer to 

the Adjustments section for timer setting chart (page 8).

P633

10218 070913

ELECTRICAL REQUIREMENTS

 

This grinder has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp, single 

phase, 60 Hz for 120V models and 230 volts ac, 10 amp single phase, 50 Hz for 230V models..

CE REQUIREMENTS

• This appliance must be installed in locations where it can be overseen by trained personnel.

• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

• Appliance shall not be tilted more than 10° for safe operation.

• An electrician must provide electrical service as specified in conformance with all local and national codes.

• This appliance must not be cleaned by water jet.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of 

this appliance by a person responsible for its safety.

• Children should be supervised to ensure they do not play with the appliance.

 If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with 

a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

• Machine must not be immersed for cleaning.

Содержание G9-2 HD

Страница 1: ...CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 To ensure you have the latest revision of the Operating Manual or to view the Illustrated Parts Cat...

Страница 2: ...hat are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the...

Страница 3: ...Electrical Requirements 4 CE Requirements 4 Operating Controls 4 Initial Set Up 5 Cleaning 5 Preventive Maintenance 5 Coffee Grinding 6 Adjustments 7 INTRODUCTION This equipment will store up to six...

Страница 4: ...0 volts ac 15 amp single phase 60 Hz for 120V models and 230 volts ac 10 amp single phase 50 Hz for 230V models CE REQUIREMENTS This appliance must be installed in locations where it can be overseen b...

Страница 5: ...t the grinder from the power source 3 Remove the upper front inspection panel 4 Remove the two screws holding the front cover to the burr housing Carefully remove the burr housing front cover Clean in...

Страница 6: ...funnel into the funnel rails and push until it stops 4 Momentarily press the start switch The grinding action will stop automatically after the preset amount of ground coffee is dispensed into the fu...

Страница 7: ...ction until a metallic whine is heard due to the rubbing of the grinding burrs It may be necessary to start more than one grind cycle to obtain this sound 7 Early Models only make a mark with a pen on...

Страница 8: ...d and amount of coffee de sired 4 Plug in the grinder Select either the right or left hopper with the selector switch Do not press the start switch 5 If grinder has an analog timer proceed to step 6 I...