USER NOTICES

The notices on this brewer should be kept in good condition.  Replace unreadable or damaged labels.

This equipment must be installed to comply 

with the International Plumbing Code of the 

International  Code  Council  and  the  Food 

Code Manual of the Food and Drug Adminis-

tration (FDA). For models installed outside 

the  U.S.A.,  comply  with  the  applicable 

Plumbing /SanitationCode.

00658.0000

00656.0000

00831.0000

27040 011108

12364.0000

20201.5600

37881.0000

Содержание DUAL

Страница 1: ...O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates Contact Bunn O Matic Corporation at 1 800 286 60...

Страница 2: ...n BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor w...

Страница 3: ...must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Adminis tration FDA For models installed outside the U S A comply with the applicable Plumbing SanitationCode 00658 0000 00656 0000 00831 0000 27040 011108 12364 0000 20201 5600 37881 0000 ...

Страница 4: ... inlet fitting is 1 4 flare NOTE Bunn O Matic recommends 1 4 copper tubing for installations of less than 25 feet and 3 8 for more than 25 feet from the 1 2 water supply line A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in ...

Страница 5: ...art of a brew cycle until the water has heated to the optimum brewing temperature 1 Remove the front panel beneath the sprayhead Models with electronic control assemblies Place the tank heater switch at the top of the control assembly in the OFF position Replace the front panel Models with electro mechanical thermostats Rotate the control thermostat knob fully counterclockwise to the OFF position ...

Страница 6: ... tank is properly filled and a funnel and server are in place 1 Modifying batch sizes To modify a batch volume first check that the SET LOCK switch is in the SET posi tion on the circuit board To increase a batch size Press and hold the START or BREW switch until three clicks are heard Release the switch Failure to release the switch within two seconds after the third click causes the volume setti...

Страница 7: ...set timer models only Placing the switch in the 1 2 Gal 1 Gal or 11 2 Gal position selects the amount of coffee to be brewed in sub sequent brew cycles Repositioning this switch after a brew cycle has been initiated does not change the brew batch in progress ON OFF SWITCH Placing the switch in the unlighted lower position cuts power to the brew station warmer and stops brewing Stopping a brew cycl...

Отзывы: