![Bunn AXIOM BREWWISE Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/bunn/axiom-brewwise-series/axiom-brewwise-series_installation-and-operating-manual_2830812020.webp)
Page 20
TOO HOT-WILL
COOL TANK NOW
ACCURACY RISK!!!
OK CAL.
CALIBRATE NOW?
NO YES
Select YES for calibration. Selecting NO warns of accuracy
risk
Select CAL. to start calibration procedure. Selecting OK will
skip to level probe calibration screen.
Automatically checks to see if tank temperature is between
130°-170°F (54°-76°C)
Go to CAL
LP1-LP2
PRESS BREW WHEN
CONTAINER READY
Verify brew funnel and decanter/thermal server (depending on
which model you have) are in place. Then press the "BREW
START" button.
COOLING TANK
PLEASE WAIT
Message will be displayed while dispense is being performed.
Tank heaters are turned off and the unit will dispense for ~1
minute to cool tank temperature.
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
39130.4 040212
FACTORY DEFAULTS
NO YES
SERVICE TOOLS ?
NO YES
BREW COUNTERS ?
NO YES
Tracks the total number of brew cycles completed. There is one
reset-able counter, and one life counter that is not reset-able
Allows the testing of individual components and the ability to
check the membrane switches for proper function. (Diagnostic
tool for troubleshooting purposes only)
Reset ALL of the previously entered brew settings, ad mes-
sage, calibrations, etc. Factory-set default values will replace
ALL previous settings.
NOTE: Items not affected; Service #, Password, Language,
Units, Asset #, Counters and Serial Number.