ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)

ENABLE ADS
This function allows the operator to choose wheth-
er or not to display an advertising message. An 
ad can be saved to the brewer by writing the ad 
using the programming commands. This message 
will be displayed when the brewer is idle.

Procedure to Enable/Disable Ads:
1.  Press and hold the right hidden switch until 

the display reads "BrewWIZARD" then release. 
Press and release the right hidden switch until 
the display reads "ENABLE ADS ?". The "YES" 
or "NO" will be flashing to indicate the current 
selection.

2.  Press and release the "NO" switch to disable 

this function, or:

3.  Press and release the "YES" switch to enable 

this function.

4.  When finished, press and release "DONE" to 

save the new setting and advance to the next 
function screen.  

5.  If "NO" was selected, the display should now 

read "ENTER SERVICE #?". To exit program-
ming and return to the MAIN SCREEN, press 
and release the "ENABLE BREW ON/OFF" 
switch.

6.  If "YES" was selected, the display should now 

read "NEW AD?".  This screen allows you to 
write a new ad.

7.  The display should now read "2 LINES 16 

CHARS AVAILABLE", and then "SCROL 
THRU ALPHA, NEXT -> NEXT LETTER", and 
then "WRITE TOP LINE?". The ad can be up 
to 32 characters long, 16 per line. The ad will 
be written in two steps, first the top line, then 
the bottom line.

9.  To write the top line of a new ad, press and 

release "YES". To skip the top line and only 
write a bottom line, press and release "NO" 
and proceed to step 13.  To exit program-
ming and return to the MAIN SCREEN, press 
and release the "ENABLE BREW ON/OFF" 
switch.

10. The display will now read "A" with a flashing 

cursor below it. Press and hold the "SCROLL" 
switch to scroll through the alphabet and avail-

able characters. When the desired character 
is shown on the display, press and release 
"NEXT" to move to the next character in the 
top line. 

11. Repeat step 10 until the top line is com-

plete.

12. Press and release "DONE". The display should 

now read "WRITE BTM LINE?".

13. To write the bottom line of the new ad, press 

and release "YES".  

14. To skip the bottom line, press and release 

"NO".

 

a.  If neither a top nor bottom line was writ-
ten, the display should now read "ENTER 
SERVICE #?".  

  b.  If only a top line was written, the ad will 

be displayed followed by "SAVE?" Proceed to 
step 18.  

15. The display will now read A with a flashing 

cursor below it.  Press and hold the "SCROLL" 
switch to scroll through the alphabet and avail-
able characters.  When the desired character 
is shown on the display, press and release 
"NEXT" to move to the next character in the 
bottom line. 

16. Repeat step 15 until the bottom line is com-

plete.

17. Press and release "DONE".  The display will 

now show the written ad, and then "SAVE?"

18. To cancel saving the ad, press and release 

"NO".  The display should now read "ADVER-
TISEMENT NOT SAVED!" and then will return 
to the "NEW AD" screen.  To exit program-
ming and return to the MAIN SCREEN, press 
and release the "ENABLE BREW ON/OFF" 
switch.

19. To correct or edit the ad, press and release 

"EDIT".  The display should now read "WRITE 
TOP LINE?"  Repeat steps 10 though 17.

20. To save the ad as it is shown, press and re-

lease "YES".  The display should now read 
"ADVERTISEMENT SETUP COMPLETE", 
and then "ENTER SERVICE #?".  To exit pro-
gramming and return to the MAIN SCREEN, 
press and release the "ENABLE BREW ON/
OFF" switch.

39130.4 040212

Содержание AXIOM BREWWISE Series

Страница 1: ...ision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quicke...

Страница 2: ...es that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that...

Страница 3: ...applicable Plumb ing Sanitation Code for your area Optional Field Wiring 120 208 240 V 15 6 17 5 A 2980 3850 W 1PH 3 Wire GND 60HZ 29710 0007 37881 0002 INTRODUCTION This equipment will brew a 1 2 ga...

Страница 4: ...k 10 Set voltage switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plum...

Страница 5: ...res Suitable For At Least 90 C 194 F FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Si...

Страница 6: ...unter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow 1 Insert...

Страница 7: ...tip carefully remove the brew funnel and discard the grounds and filter 39130 4 040212 D A ENABLE BREW ON OFF SWITCH Pressingthe ENABLEBREWON OFF switch indicatoron supplies power to the brew station...

Страница 8: ...problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable the Recovery Booster and Pu...

Страница 9: ...to their specifications PROGRAMMING SWITCHES 1 FUNCTION SCREEN This is the display which shows the various functions 2 Right of the display This is used to access the program mode and is also used to...

Страница 10: ...DONE ENTER PASSWORD 0 0 0 BREW LOCKOUT NO DONE YES PROGRAMMING FUNCTIONS OVERVIEW BrewWIZARD EXITING BrewWIZARD UNITS METRIC DONE ENG SET LANGUAGE NO YES SET PASSWORD 0 0 0 ENTER SERVICE NO YES BREW O...

Страница 11: ...xx xx FACTORY DEFAULTS NO YES SERVICE TOOLS NO YES BREW COUNTERS NO YES ENABLE BrewLOGIC NO DONE YES 0 REFILL 155 DONE ENABLE CLEAN NO DONE YES SET PULSE BREW NO YES ADJUSTMENTS OPTIONAL SETTINGS CON...

Страница 12: ...o the MAIN SCREEN Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SER VIC...

Страница 13: ...TTINGS CONT This function allows the operator to adjust the brew strength extraction time Setting 1 will produce a non pulsed brew cycle and the highest 14 will give you the longest time utilizing pul...

Страница 14: ...right hidden switch until the display reads AXIOM VERSION Press and release the right hidden switch until the display reads CALIBRATE FLOW 3 Select YES The display should read CONTAINER READY If cont...

Страница 15: ...ON OFF switch 10 The display will now read A with a flashing cursor below it Press and hold the SCROLL switchtoscrollthroughthealphabetandavail able characters When the desired character is shown on t...

Страница 16: ...NE YES SCROL THRU ALPHA NEXT NEXT LETTER A SCROLL DONE NEXT WRITE BTM LINE NO YES SAVE NO EDIT YES ADVERTISEMENT SETUP COMPLETE ADJUSTMENTS OPTIONAL SETTINGS CONT ENTER SERVICE ENTER SERVICE ADVERTISE...

Страница 17: ...red 5 Press and release the DONE switch The displaywillnowread EXITINGBrewWIZARD and then ENTER PASSWORD ENTER PASSWORD This function allows the operator to enter a 3 digit number to access LEVEL 2 If...

Страница 18: ...O YES NOTE If the brewer is set for Metric Units displays will be different ex Brew oz will become Brew milliliters F will be C Adjusts brew tank temperature RANGE 185 to 205 F or 85 to 96 C This func...

Страница 19: ...or reduce the tank temp to 140 F or 60 C once the set idle time has expired Range 0 5 24 0 hrs Enabl EnergySavr NO DONE YES 39130 4 040212 0 REFILL 155 DONE Adjusts the sensitivity of the refill circu...

Страница 20: ...ispense is being performed Tank heaters are turned off and the unit will dispense for 1 minute to cool tank temperature ADJUSTMENTS OPTIONAL SETTINGS CONT 39130 4 040212 FACTORY DEFAULTS NO YES SERVIC...

Отзывы: