PLACE BREWER IN
FINAL LOCATION
Select a sturdy, level location.
Brewer must not be bumped during calibration!
"EASY PULSE BREW" times:
Min: Base brew time + 40 seconds
Max: Base brew time + 3:00 minutes
DRIP TIME 1:00
(-) DONE (+)
ENABLE CLEAN
NO DONE YES
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
Adjusts the DRIP TIME (time from end of sprayhead flow to
when liquid stops dripping from the funnel). When the brew
cycle is complete, the display will show "DRIPPING" and will
countdown the time until the funnel empties.
RANGE: "OFF" or 0:05 to 4:00 minutes
Set the time before a cleaning alert will be displayed.
RANGE: 1 to 30 days
Enables the mode function and sets the idle time. Then choose
to have the tank heater(s) turn off, or reduce the tank temp to
(140° F) or (60° C) once the set idle time has expired.
Range: 0.5 - 24.0 hrs
Enabl EnergySavr
NO DONE YES
39130.4 040212
0 REFILL 155
(-) DONE (+)
Adjusts the sensitivity of the refill circuit. Water in different
geographical locations can have different conductivities. Make
sure the water in the tank is touching the refill probe.
NOTE:
Always make sure that the # on the right is larger than the #
on the left when water is contacting the tank refill probe.
(CONT.)
ENABLE BrewLOGIC
NO DONE YES
The BrewLogic system allows the brewer to be calibrated to
high mineral locations and compensate as deposits build up
internally. Press YES, then press DONE. Follow the prompts.
Pertains only to software version 1.07 & above!
ENABLE BrewLOGIC
NO DONE YES
The BrewLogic system allows the brewer to be calibrated to
high mineral locations and compensate as deposits build up
internally. Press YES, then press DONE. Follow the prompts.
Go to
SPRAY OZ/M: