When the machine is to be used again
※ When the machine is to be used again, check the following items and machine is
operated.
① Take off the safekeeping cover on the machine.
② Clean the air-filter and evaporator, re-install it indoor unit.
③ Check the air inlet and outlet of the indoor/outdoor are not blocked.
④ How to check V-belt tension
If V-belt tension is not normal, fan does not operate normally. When pressing fan V-belt
with hand, it should be pressed down 10mm or so.
CAUTION
Turn off the circuit breaker surely, before checking.
When the machine is to be finished
① Turn off the circuit breaker surely.
② For prevent drain pipe clogged, remove dust in the drain pipe,
③ Condensed water should be fully drained. If the drainage is incomplete, water may be
freezing and drain pipe will cause breakdown.
④ Operated the machine on air circulation mode for 2 to 3 hours. because drying inside the
machine.
⑤ When the machine is stopped for a long time, put the machine on the safekeeping cover.
⑥ When the machine is operated during spring or fall, operated the machine on air circulation
mode.