PA30 Series Powered Air-Purifying Respirator

PA3/PA3IS Blower Assembly User Manual

Mounting the Breathing Tube on the
PA3BU/PA3ISBU Blower

Ensure that a rubber gasket is in place in the breathing tube
coupler on the blower unit.

Screw one end of the breathing tube into the blower unit (hand
tight is sufficient)

(see Figure 2)

.

Ensure that neither the breathing tube nor the filter is blocked.

Ensure that the ON/OFF Switch is in the OFF position. 

Switch on the blower. If the Low Voltage Alarm sounds at this time,
the battery needs to be recharged. See instructions on page 4
regarding properly charging the battery.

NOTE

On the PA3BU unit, the low voltage alarm will sound a
short beep as the power switch is cycled on and off,
indicating that the alarm is functioning properly. The
alarm will sound continuously to indicate low voltage.

Checking Airflow with the Airflow Indicator
(PA1AFI)

With the blower switched ON and the filters/cartridges mounted,
take the free end of the breathing tube in one hand, hold it upright
and place the Airflow Indicator into the end of the tube 

(see Figure 3)

.

Apply a light downward pressure to the Airflow Indicator to get a
reasonable seal at the breathing tube end. Ensure that the air
outlet holes in the Airflow Indicator tube are not blocked. Two
hands may be used if preferred, one to hold the breathing tube
and one to hold the Airflow Indicator.

The position of the ball in the Airflow Indicator should be
observed. If any part of the ball is below the PASS LINE on the
Airflow Indicator, check for:

• Blower malfunction.

• Clogged or damaged Air-Purifying filter elements on the HE

filters or the combination cartridges with HE filters. See
“Mounting and Replacing Cartridges on the Blower Unit” on
page 7.

• Low voltage or battery malfunction.

If the ball is completely above the PASS LINE on the Airflow
Indicator, then the system is ready for use.

NOTE

On the PA3BU unit, due to the back-pressure of the ball,
the Low Voltage Alarm may sound when a reading is
being taken. If the ball bounces, let it stabilize, and then
read the lowest point.

When the blower passes the flow test, it is ready to use. 

If the blower malfunctions during use in a hazardous area:

DO NOT

remove the respirator hood, blower or waist-belt while

in the hazardous area.

DO

remain calm and 

LEAVE

the hazardous area immediately.

After reaching a hazard-free area, immediately remove the
respirator.

DO NOT

use a blower that fails the flow test.

Use 

ONLY

Bullard cartridges which comply with and have the

NIOSH approval label and which are appropriate for the
contaminant.

Failure to observe these warnings could result in death or
serious injury.

WARNING

Mounting the Br

eathing T

ube/Checking Airflo

w

www.bullard.com

Figure 2

Figure 3

Gasket

Содержание PA30 Series

Страница 1: ...espiratory protection during abrasive blasting or clean up 4 Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards 5 Leave area immediately if Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant Unit becomes damaged Voltage a...

Страница 2: ...erational Inspection 4 Mounting the Breathing Tube 5 Checking Air Flow 5 Air Purifying Elements 6 Mounting and Replacing Cartridges 7 Donning the Blower 8 Low Battery Alarm 8 Troubleshooting 9 Cleaning and Storage 9 NIOSH Approval Label 10 11 Ordering Information 12 Table of Contents 2 www bullard com ...

Страница 3: ...Hat 20SICVH Hood with Taped and Sealed Seams and CBRN resistant PVC lens for use with Bullard Hard Hat 20TPC Hood with Solvent Resistant Lens and Inner Bib 20TP Hood with Solvent Resistant Lens 20LFM Loose Fitting Facepiece Hood Medium Size 20LFL Loose Fitting Facepiece Hood Large Size 6 The Battery Charger PA3SMC Quick Charger PA3GC Gang Charger PA3ISC Intrisically Safe Quick Charger PA3ISGC Intr...

Страница 4: ... is fully charged This procedure should also be followed after periods of prolonged storage Without periodic charging the nickel metal hydride batteries will lose up to 1 2 of their charge per day Allowing a battery to self discharge during periods of prolonged storage will not damage the battery Pre Operational Inspection Prior to each work shift perform the following Pre Operational Inspection t...

Страница 5: ... not blocked Two hands may be used if preferred one to hold the breathing tube and one to hold the Airflow Indicator The position of the ball in the Airflow Indicator should be observed If any part of the ball is below the PASS LINE on the Airflow Indicator check for Blower malfunction Clogged or damaged Air Purifying filter elements on the HE filters or the combination cartridges with HE filters ...

Страница 6: ...inst the following contaminants independent laboratories have tested and verified that the PA3NBC cartridge is effective against many chemical warfare agents and or their recognized surrogates These agents surrogates are listed below WARNING Use only the cartridge described in the above table Used particulate laden cartridges must be changed as a set and not individually All cartridges must be of ...

Страница 7: ...cts of the gas or vapor and the presence of any warning properties Contact Bullard for further information on change out schedules High efficiency particulate filters must be replaced when retained particles clog the filters and reduce air flow below acceptable levels as indicated by testing with the Air Flow Indicator See page 5 To Replace Cartridges Remove the air purifying element from its pack...

Страница 8: ... if the battery voltage is below acceptable levels The PA3BU Low Voltage Alarm is an electronic 77 dba beep The PA3ISBU Low Voltage Alarm is a mechanical pulsing of the blower In either case the alarm is internal to the blower and the sound will be carried up the breathing tube into the hood Sounding of the alarm indicates that insufficient airflow may be imminent The user should immediately do th...

Страница 9: ...ne organic based solvents or chlorinated degreasing fluids such as trichloroethylene as they will cause damage DO NOT immerse the equipment in water or other cleaning fluid as this may cause contamination in the breathing tube and blower interior that will be difficult to remove Failure to observe the instructions and warnings in this manual invalidates all performance statements and approvals for...

Страница 10: ...s for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenanc...

Страница 11: ... for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance...

Страница 12: ...olvent resistant polyester lens no suspension CC20 only Hood with inner bib for use with Bullard hard hat 20TICH Tychem QC hard hat not included 20SICH Tychem SL with taped and sealed seams hard hat not included 20SICVH Tychem SL with taped and sealed seams and CBRN resistant PVC lens hard hat not included Hood with inner bib and long outer bib for use with headband suspension 20TICS Tychem QC wit...

Отзывы: