4-36
User’s Guide
–
If the domain is operating normally,
RUNNING
is displayed in the
Domain State
field.
–
If the domain has been automatically powered down,
INACTIVE
is displayed in the
Domain State
field. See Table 27.
System Functional Status / Expected Domain
State
Managing Domains
Warning:
If system functional status is critical (flashing red icon), immediately save data, close
open applications and shut down the domain Operating System.
System Functional Status / Expected Domain State
Icon
System Functional Status
Expected Domain State
Green
NORMAL
RUNNING
Yellow
WARNING
RUNNING
Orange
CRITICAL
INACTIVE
(auto Power OFF
) / RUNNING
An automatic
Power OFF
request may be
sent by PAM software to the domain Operat-
ing System:
–
If the domain Operating System is
configured to accept PAM
Power OFF
requests, it automatically saves data,
closes open applications and shuts down.
–
If the Operating System is not configured
to accept PAM
Power OFF
requests, you
Orange
Flashing
–
If the Operating System is not configured
to accept PAM
Power OFF
requests, you
are advised to manually save data, close
open applications and shut down the
Operating System.
Note:
When system functional status is FATAL, the
icon does not always remain red. Therefore,
an orange functional status icon may indicate
a FATAL hardware status.
Red
FATAL
INACTIVE
An automatic
Force Power OFF
command
may be performed by PAM software on the
domain Operating System.
Note:
Red
Flashing
domain Operating System.
Note:
The Operating System does not have time to
save data and close applications before it is
shut down.
Purple
NOT ACCESSIBLE
INACTIVE
Table 27.
CSS functional status / domain state
3. Toggle the
PAM Tree
to view hardware functional status (round, colored indicator next to
the
Hardware Monitor
node). The PAM Tree will automatically expand down to the
faulty hardware element.
4. Check domain state by clicking
Domain Manager
in the PAM tree.
5. Click the faulty hardware element to open the corresponding
Hardware Status
page.
6. Check
Power
and
Temperature
tabs. If a power and/or temperature indicator is NOT
green, a power– and/or temperature–specific fault has occurred. See
Power Status
Indicators
and
Temperature Status Indicators
Содержание NovaScale 5 5 Series
Страница 1: ...Bull NovaScale 5xx5 6xx5 User s Guide 86 A1 41EM 00 ORDER REFERENCE...
Страница 2: ......
Страница 27: ...xxv Preface AZERTY QWERTY Keyboard Lookup Table Figure 1 AZERTY keyboard Figure 2 QWERTY keyboard...
Страница 52: ...1 24 User s Guide...
Страница 76: ...2 24 User s Guide...
Страница 168: ...5 2 User s Guide...
Страница 288: ...User s Guide A 10...
Страница 300: ...B 12 User s Guide NovaScale 5165 Server Data Cabling Diagrams Internal Disk Configuration...
Страница 304: ...B 16 User s Guide NovaScale 6165 Server Data Cabling Diagrams Internal Disk Configuration...
Страница 362: ...C 48 User s Guide...
Страница 372: ...User s Guide G 10...
Страница 378: ...User s Guide X 6...
Страница 381: ......
Страница 382: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 41EM 00 ORDER REFERENCE...
Страница 384: ......