6-45
Console Cabling Requirements
Configuration Rules for PowerConsole 2 Extensions
Additional internal disk drives and media drives must be placed in this PowerConsole
according to the following rules:
Five bays are available in Escala S100:
–
three of them are already used by: floppy, one CD–ROM 20X and one system disk of
4.5GB.
–
Two bays are free (one 1’’ and one 1.6’’). They can be used for two disk drives or for
one media and one disk drive.
The disk drives are 1’’ high, 7200tpm, with a capacity of 4.3GB and 9.1GB.
The VDAT fits only in the bay #2 (normally the bay of the CD–ROM) of the S100 and
therefore they must be swapped with the CD–ROM.
Bay 4
Bay 5
Bay 3
Bay 2
Bay 1
Front View
Figure 33. Escala S100 Peripherals Placement Information
Figure 34 sums up the possible configurations.
Peripheral
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
4.3GB Disk
Floppy
CD-ROM
Y
Basic Disk Y
9.1GB Disk
Floppy
CD-ROM
Y
Basic Disk Y
12/24GB 4mm DAT
Floppy
CD-ROM
Y
Basic Disk N
16/32GB QIC
Floppy
CD-ROM
Y
Basic Disk N
8mm VDAT
Floppy
Y
CD-ROM
Basic Disk N
Figure 34. Escala S100 Peripherals Adding.
Содержание Escala EPC1200
Страница 1: ...Bull ESCALA EPC Series EPC Connecting Guide 86 A1 65JX 03 ORDER REFERENCE...
Страница 2: ......
Страница 14: ...1 2 EPC Connecting Guide...
Страница 22: ...4 4 EPC Connecting Guide...
Страница 76: ...6 46 EPC Connecting Guide...
Страница 80: ...7 4 EPC Connecting Guide...
Страница 85: ...7 9 Fast Ethernet Interconnect Requirements Figure 38 Redundant Fast Ethernet Interconnect for 3 to 8 Nodes...
Страница 90: ...7 14 EPC Connecting Guide...
Страница 94: ...8 4 EPC Connecting Guide Cabling Diagrams Figure 42 Gigabit Ethernet Interconnect for 2 Nodes...
Страница 100: ...8 10 EPC Connecting Guide...
Страница 106: ...9 6 EPC Connecting Guide Figure 52 INTCF06 FDDI Interconnect with Hub Dual Homing...
Страница 110: ...9 10 EPC Connecting Guide...
Страница 115: ...10 5 Disk Subsystems Cabling Requirements Figure 55 SSACF01 Loop diagram 1 to 4 nodes 1 SSA cabinet 1 to 4 segments...
Страница 130: ...10 20 EPC Connecting Guide Figure 72 Cabling schema with FIbre Optical Extenders 1 or 2 nodes 1 SSA cabinet on each side...
Страница 162: ...10 52 EPC Connecting Guide XLOOP02 2 Nodes Dual Loop 4 Hubs 2 DAS Figure 110 XLOOP02 2 Nodes Dual Loop 4 Hubs 2 DAS...
Страница 186: ...11 2 EPC Connecting Guide...
Страница 194: ...12 8 EPC Connecting Guide...
Страница 204: ...A 10 EPC Connecting Guide...
Страница 206: ...B 2 EPC Connecting Guide...
Страница 212: ...D 4 EPC Connecting Guide...
Страница 214: ...G 2 EPC Connecting Guide...
Страница 218: ...X 4 EPC Connecting Guide...
Страница 221: ......
Страница 224: ......