6-27
Console Cabling Requirements
If there is no Cluster Administration Hub, that is to say no dedicated administration network,
the Console Concentrator and the Cluster Console will be connected to the customer’s LAN
network (an Ethernet network) in the customer’s premises.
In the case that the customer’s network is COAXIAL THICK or COAXIAL THIN then the
Customer is in charge of connecting the Console Concentrator and the Cluster Console to
his network with his own cables (As usual for all the Escala platforms).
A second Cluster Console can also be ordered to act just as an X terminal on the
customer’s Ethernet LAN, and thus to provide a second point for remote management.
Cabling Diagrams
Figure 17. Cluster Console with Powercluster 2 Nodes and >2 Nodes
Cabling Legend
Item M.I.
Designation
Length
FRU
CBL1912
Cable, Adapter RS232 (9M/25M)
0.3m
76958073-002
CBLG104-2000
Cable, local RS232 (25F/25M)
15m
90232001-001
CBLG105-1800
Cable, local RS232 (25F/25F)
7.5m
90233002-001
CBLG106-2000
Cable, remote RS232 (25M/25F)
15m
90234001-001
CBL2101
V24/V28 conn. cable (25M/25F)
3.6m
90479001-001
CBLG161-1900
Cable, Ethernet crossed RJ45/RJ45
10m
91093001-001
CBLG179-1900
Cable, Ethernet RJ45/RJ45 cat 5
10m
91094001-001
VCW3630
Cable, Ethernet to transceiver
5m
76958087-001
Содержание Escala EPC1200
Страница 1: ...Bull ESCALA EPC Series EPC Connecting Guide 86 A1 65JX 03 ORDER REFERENCE...
Страница 2: ......
Страница 14: ...1 2 EPC Connecting Guide...
Страница 22: ...4 4 EPC Connecting Guide...
Страница 76: ...6 46 EPC Connecting Guide...
Страница 80: ...7 4 EPC Connecting Guide...
Страница 85: ...7 9 Fast Ethernet Interconnect Requirements Figure 38 Redundant Fast Ethernet Interconnect for 3 to 8 Nodes...
Страница 90: ...7 14 EPC Connecting Guide...
Страница 94: ...8 4 EPC Connecting Guide Cabling Diagrams Figure 42 Gigabit Ethernet Interconnect for 2 Nodes...
Страница 100: ...8 10 EPC Connecting Guide...
Страница 106: ...9 6 EPC Connecting Guide Figure 52 INTCF06 FDDI Interconnect with Hub Dual Homing...
Страница 110: ...9 10 EPC Connecting Guide...
Страница 115: ...10 5 Disk Subsystems Cabling Requirements Figure 55 SSACF01 Loop diagram 1 to 4 nodes 1 SSA cabinet 1 to 4 segments...
Страница 130: ...10 20 EPC Connecting Guide Figure 72 Cabling schema with FIbre Optical Extenders 1 or 2 nodes 1 SSA cabinet on each side...
Страница 162: ...10 52 EPC Connecting Guide XLOOP02 2 Nodes Dual Loop 4 Hubs 2 DAS Figure 110 XLOOP02 2 Nodes Dual Loop 4 Hubs 2 DAS...
Страница 186: ...11 2 EPC Connecting Guide...
Страница 194: ...12 8 EPC Connecting Guide...
Страница 204: ...A 10 EPC Connecting Guide...
Страница 206: ...B 2 EPC Connecting Guide...
Страница 212: ...D 4 EPC Connecting Guide...
Страница 214: ...G 2 EPC Connecting Guide...
Страница 218: ...X 4 EPC Connecting Guide...
Страница 221: ......
Страница 224: ......