4.3
Checking correct operation
To check for bullx blade system’s correct operation:
•
Ensure that the following LEDs are glowing – CMM ID should be blinking,
irrespective of the Power Mode setting, you should see:
a.
The CMM ID LED starts blinking after a few seconds of power On.
b.
The Fan Fault LED should not be glowing.
•
If Start Power Mode is set to Unlocked Power, then the bullx blade chassis fans should
start running and the Power LED on the blade should be Amber (the blade is in stand
by mode)
•
If Start Power Mode is set to Full Power On, then the bullx blade chassis fans should
start running and the Power LED on the blade should be Amber (the blade is in stand
by mode). After a few seconds, the Power LED should turn Green
Note
Default Start Power Mode is Unlocked Power.