GUIDELINES FOR INSTALLING LP GRILL INTO AN OUTDOOR KITCHEN
1)
Vents must be provided for combustion air and ventilation on both sides of built-in cabinet.
2)
When choosing a location for your gas grill keep in mind that it should never be located under any overhead combustible construction.
3)
Per illustration, the sides and back of the grill should not be any closer than
21 inches
to combustible construction.
4)
Per CSA, it is required that any built-in cabinet must have enough room for only 1 LP tank. The LP tank enclosure must not
exceed (24.5” X 24.5” X 30”) and there must be a minimum clearance of 2 inches between the floor and the propane tank
enclosure.
(DO NOT STORE EMPTY OR FULL SPARE TANKS UNDER OR NEAR THIS OR ANY OTHER APPLIANCE)
5)
There must be a minimum of 6 inches counter space behind the grill in order to allow the grill hood to clear properly.
6)
The cylinder valve on the LP tank must be readily accessible for hand operation.
7)
The LP tank must be isolated enough to where it is shielded from radiant heat and open flames.
8)
The LP tank must be protected from foreign matter such as hot drippings.
9)
There must be access so the LP tank can be connected, disconnected, inspected and leak tested outside of the cabinet.
10)
The enclosure must provide access to allow leak testing of LP connections inside the enclosure for the LP Tank
11)
The connectors must comply with ANSI Z21.75 CSA 6.27 standard for Connectors used on Outdoor Gas Appliances and
Manufactured Homes to be suitable for outside installation.
12)
The instructions shall indicate that the maximum length of the connection shall be 6 ft.
13)
Please ensure visibility of the connector and directions for the piping, flexible tubing and gas connector within enclosure.
14)
Do not use any combustible materials for this construction.
NO COMBUSTIBLE
CONSTRUCTION
MATERIALS ALLOWED
WITHIN 21 INCHES OF
THE BACK AND BOTH
SIDES OF SIDE
BURNER OR GRILL
NON-COMBUSTIBLE
CONSTRUCTION REQUIRED
LP PLUMBING
SUPPLIED BY BULL:
GRILL FLEX LINE
3/8 FLARED ‘T’
FITTING
SIDE BURNER LP
LINE
LP HOSE LINE
WITH REGULATOR
SUPPLIED BY BULL
NOTE: LP TANK TO GRILL
AND SIDE BURNER MUST BE
SECURED TO ISLAND
(MOUNTING HARDWARE NOT
SUPPLIED BY BULL)
SIDE BURNER FLEX TUBE
3/8 INCH UNION
FLARE FITTING AND
LP HOSE
SUPPLIED BY BULL
SIDE BURNER