background image

Page | 3 

INTRODUCTION 

 

Thank you for your purchase of a Built Right pool and spa heat pump, proudly made in Punta 
Gorda, Florida.  To ensure a long worry-free life, your heat pump has been manufactured with the 
highest quality parts available today.  A pool heat pump is a cost effective method of heating your 
pool or spa.  Your Built Right heat pump will provide you with years of pool enjoyment.  Your new 
heat pump takes heat from the surrounding air and transfers it into the water.  The warmer the air 
and the more humid the air, the more heat is available for heating your pool.  The ideal or rated 
condition for the heat pump is 80

F air temperature, 80% relative humidity, and 80

F water 

temperature.  This is true with all air source pool heat pumps.  Under ideal conditions, a properly 
sized heat pump should raise your pool temperature 1

 F. per hour.  As air temperature and 

humidity decrease, performance will also decrease. 
  
The most efficient time to heat your pool is during daylight hours when outside temperatures are 
the greatest.  Adjustments to your pool pump runtime may be necessary to maintain desired 
temperature.  Like your home air conditioner, it is recommended to set a desired temperature and 
leave it.  A heat pump is best utilized for maintaining a set water temperature.  It’s not intended to 
provide fast heating.  When not in use for long periods of time, it is acceptable to shut off your 
heat pump.  When you have a desire to heat your pool, plan accordingly, because it may take the 
heat pump days to heat your pool back to your desired temperature.  The time it takes to heat 
your pool back up, will depend on your pool temperature and outdoor conditions. 
 
Your heat pump will operate when temperatures drop at night, but BTU output will also decrease. 
When the outdoor temperature drops below 45

 F, it is not advisable to operate the pool heat 

pump.  Below 45

 F, there is insufficient heat in the air to adequately warm the pool.  As with all 

pool heating methods, you are advised to utilize a pool cover at night and when the pool is not in 
use.  A pool cover is recommended if the night temperature is 15

F (8

C) less than the desired 

pool temperature.  The cover will help reduce heat loss by limiting evaporation, greatly reducing 
the overall pool heating costs.  The proper use of a cover can reduce operating cost by as much as 
50% under certain conditions. 
 
Proper installation and use of your heat pump will result in increased performance and reduced 
heating costs.  Your pool heat pump is designed for lower maintenance at a lower cost.  But if you 
want your pool heated efficiently, you must follow the advice we supply in this manual. 

 

 

Содержание BR100 S7

Страница 1: ...Pool Spa Heat Pump Installation Operation Manual Models BR80 XW BR115 XW BR135 XW BR100 S7 BR115 S7 BR135 S7 BR 40101 Version 2 0...

Страница 2: ...ida is 50 fifty US dollars Claims for warranty reimbursement must have prior authorization by Built Right and be performed by a Factory Authorized Service Agent This warranty is void if the product is...

Страница 3: ...Wiring Diagram 7 Heat Pump Operation Digital Control Operation 8 10 Control On Off 8 Pool Spa Mode 9 Displaying the Temp in F or C 9 Keypad Lockout Feature 9 Changing Set Point Temperature 10 Heater...

Страница 4: ...________________________________________ Dealer Name _____________________________________________________________________ Dealer Address ______________________________________________________________...

Страница 5: ...mp is best utilized for maintaining a set water temperature It s not intended to provide fast heating When not in use for long periods of time it is acceptable to shut off your heat pump When you have...

Страница 6: ...values are different from those specified use the greater value to ensure safe and proper installation Equipment Pad Install the heat pump on a flat slightly pitched surface preferably a concrete or f...

Страница 7: ...r level isolation valves must be installed The pool heater should not be installed more than 6 feet below the pool water surface or no more than 15 feet above the pool level Be advised that when pool...

Страница 8: ...s of a pool structure including reinforcing steel metal fittings and above ground equipment be bonded together with a solid copper conductor not smaller than 8 AWG The heat pump along with pumps and o...

Страница 9: ...0 Black Orange 230V Red Wire Use for 208 V Application Legend Comp Compressor CC Compressor Capacitor EVAP Defrost Temp Sensor FC Fan Capacitor FM Fan Motor HPS High Pressure Switch LPS Low Pressure S...

Страница 10: ...urn heater on Press the set button until the word Off appears Press down button until No appears Heater is now on Pool Spa lights will illuminate beside display indicating heater is on Use the up or d...

Страница 11: ...ess the SELECT button for 5 seconds and the display will show spacing for a two digit code _ _ at the right hand side Press Up and Down buttons to enter the code starting from 00 to 99 Enter the code...

Страница 12: ...the pump is activated You will then need to set the water temperature to your desired set point The heater will start after a three minute time delay if the desired set point is higher than the actua...

Страница 13: ...sive simply rinse the evaporator coil with fresh water Use of a garden hose with low water pressure will work best Use extra care so that you don t bend the coil fins The heater s housing is made from...

Страница 14: ...basket pump strainer basket and pool filter are all clean Ensure valves are set properly Control Display is flashing FS Or FS1 FS2 FS3 FS4 Air temperature is too cold for heater operation Wait until...

Страница 15: ...ill assure you of in warranty service Notes ________________________________________________________________________________ ___________________________________________________________________________...

Страница 16: ...Built Right Pool Heaters LLC 8260 Pascal Dr Punta Gorda Fl 33950 4726 www BuiltRightPoolHeaters com...

Отзывы: