![Buhnen HB 700 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/buhnen/hb-700/hb-700_operating-manual_2828288011.webp)
11
5.2
Troubleshooting
Fault
Possible cause
Remedy
See Section
Nozzle goes on dripping
Nozzle valve partially ob-
structed or damaged
Drain the device. Actuate
the trigger for approx. 5 s to
clear the nozzle.
HB700:
Clean or replace nozzle end
HB 700 Spray:
Clean or replace swirl nozz-
le, pressure spring and ball
6.2
Too little or no melt is dischar-
ged
Operating pressure too low Increase operating pressure
(max. 87 psi / 6 bar)
4.3
Compressed-air supply
disconnected
Check compressed-air
supply
Nozzle system clogged
HB700:
Clean or replace cone nozz-
le and if necessary nozzle
end
HB 700 Spray:
Clean or replace swirl nozz-
le, pressure spring and ball
6.2, 6.3
Stock temperature too low
Raise temperature
3.3.1
Compressed air escapes from
closure cap (11)
Insufficient cover pressure
Increase cover pressure
6.4
Gasket dirty
Clean sealing faces
Compressed air escapes from
service unit
Connections not airtight
Tighten or replace gaskets
Sight glass of water sepa-
rator (2) cracked
Replace sight glass
HB 700 Spray only
Spray pattern not ideal
Spray pattern wrongly set
Adjust spray air
4.4
Nozzle system clogged or
damaged
Clean or replace swirl nozz-
le, pressure spring and ball
6.3.4