61
After setting the required helium content, the device will go to ACTIVE option.
5)
Mark the edited gas mix as active
or inactive
. Only active
gas mixes can be selected by the user while diving and planning a dive (by Dive
Planner).
Repeat steps 2) for all gases.
The gas list is saved when you exit the current screen (button
).
Switching the device off while in edit mode will discard the current settings.
Sample gas mix table view after entering
the parameters:
After each edit of the gas mix table, the
dive
computer
will
automatically switch to the option , requiring the current gas to be re-set. Use the
CONFIRM button to select the right mix of gases marked active (cyclically switched). The
current selection is presented at section:
SELECTED
–
name of the currently selected gas mix
MOD
–
maximum depth of a dive with selected gas, calculated for 1.6Bar Oxygen
partial pressure, in meters [m] or ft [ft]
6.1.2.3
Dive parameters configuration
–
DIVE SETUP.
All the parameters set here are used in
planning a dive (Dive Planner).
The values entered also affect decompression
stops, NDL, TTS, CNS and OTU.
Содержание ZHL-16C GF
Страница 1: ...DIVECOMPUTER EU USER MANUAL V4 0...
Страница 17: ...17 Dive graphs Depth graph Oxygen partial pressure graph Temperature graph Summary graph...
Страница 25: ...25 3 3 Menu layout Surface work Underwater work...
Страница 35: ...35 4 3 Menu layout Surface work Underwater work...
Страница 45: ...45 Dive graphs Depth graph Oxygen partial pressure graph Temperature graph Summary graph...
Страница 56: ...56 5 3 Menu layout Surface work Underwater work...
Страница 67: ...67 Dive graphs Depth graph Oxygen partial pressure graph Temperature graph Summary graph...
Страница 77: ...77 6 3 Menu layout Surface work Underwater work...
Страница 99: ...99 7 3 Menu layout Surface work Underwater work...