4 Maintenance
4.1 Inspection and Service
The device works maintenance free.
NV74 only:
Replace the filter element when clogged, at least once a year. In special cases, a small
amount of oil may be refilled via the Nivovent filter.
4.1.1 Replacing the Filter Element
To replace the filter element, proceed as follows:
Unscrew the filter cover counter clockwise.
Remove the filter element and dispose it according the National rules and standards.
Insert the new filter element.
Make sure that the filter element has got the correct pore size.
Close the filter cover.
For filters with visual clogging indicator: Reset the display to zero with the reset button
4.2 Refilling small Amounts of Oil
With option BFA or SSR only:
Unscrew the filter cover counter clockwise.
Refill the oil slowly.
Insert the filter element and close the cover.