P2.3C, P2.4C

1 Introduction

This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at 

www.buehler-technologies.com

Please direct any questions to:

Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany

Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20

These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.

1.1 Intended use

Sample gas pumps are intended for installation in gas ana-
lysis systems for industrial applications.

DANGER

Danger of explosion if used in a potentially explosive
atmosphere

Sample gas pumps of types P2.3C and P2.4C are not suitable
for use in potentially explosive atmospheres and must not be
placed in them.

The complete designation of the P2.3C and P2.4C sample gas
pumps is:

II 3G/- c IIB T4 X

The P2.3 C and P2.4C sample gas pumps may only be used to
convey explosion class IIA and IIB flammable gaseous media
which are not explosive during normal operation, as well as
non-flammable gaseous media.

The maximum surface temperature varies by the medium
and ambient temperatures. Please refer to the data sheets for
the correlation between media temperature, ambient tem-
perature and the pump’s temperature class. Flammable medi-
ums must not be heated beyond these values. Please note,
flammable gas must only be heated up to 80 % of its ignition
temperature. The lower of the two values is the maximum
medium temperature.

Gas sampling is generally prohibited if the gas flow results in
a dangerous electrostatic charge in the bellow / pump body
(also see chapter "Operation and Control").

The sample gas pumps are only intended to convey gaseous
media. They are not suitable for liquids.

Please note the additional information in chapter "Product
Description" and "Operation and Control" along with the in-
formation on specific intended use, existing material combin-
ations, as well as pressure and temperature limits in the data
sheets.

When installed outdoors, ensure adequate protection from
the weather, see chapter Requirements for the set-up location

1.2 Scope of delivery

P2.3C

P2.4C

1 x Sample gas pump with mo-
tor

1 x Pump body with intermedi-
ate flange

4 x Rubber-metal bumpers

1 x Motor

1 x Mounting bracket made of
1.4301

1 x Coupling flange

Product documentation

1 x Coupling

1 x Mounting ring

Product documentation

2 Safety regulations

Installation into a complete system can pose new hazards on
which the manufacturer of this sample gas pump has no
bearing. If necessary, perform a risk assessment of the com-
plete system this product will be installed into.

When configuring and building the complete system the rel-
evant national safety regulations for the installation site and
the generally applicable state of the art must be observed.
These can be determined through applicable harmonised
standards, among other things, e.g. IEC 60079-14. Additional
national regulations pertaining to initial operation, opera-
tion, maintenance, repairs and disposal must be observed.

When conveying flammable gasses, avoid potential exo-
thermic reactions in your system, do not use materials with a
catalytic effect in the conveyor lines. Dangerous rises in tem-
perature could result. Sample gas pump materials in contact
with media are listed in this operating manual to facilitate
the safety assessment.

Adiabatic compression is part of the physical operating prin-
ciple of bellows pumps. Dangerous rises in temperature can-
not be ruled out with improper exceeding of the operating
parameters. Conveying flammable gasses then pose an explo-
sion hazard.

Avoid these dangerous circumstances. If necessary, the com-
plete system should be secured against flashback. Follow
these notices and the applicable national regulations, prevent
malfunctions to avoid personal injury and property damage.

The operator of the system must ensure:

• The equipment is only installed by a professional familiar

with the safety requirements and risks,

• Safety notices and operating instructions are available

and observed,

• The permissible data and operating conditions are ob-

served,

• Protective devices are used and mandatory maintenance

is performed,

• Legal regulations are observed during disposal.

8

Bühler Technologies GmbH

BX420022 ◦ 08/2018

Содержание P2.3C

Страница 1: ...Ref 998BX420022 Analysentechnik Kurzanleitung Messgaspumpen deutsch 2 Brief Instructions Sample Gas Pumps english 8 Notice de montage Pompes de circulation fran ais 14 Gu a r pida Bombas de gases de m...

Страница 2: ...tbe schreibung und Betrieb und Bedienung sowie die Angaben der Datenbl tter hinsichtlich spezifischen Verwendungs zwecks vorhandener Werkstoffkombinationen sowie Druck und Temperaturgrenzen Bei einer...

Страница 3: ...treten hoher Gastemperaturen durch adiabatische Kompression ist m glich und vom Anwender zu pr fen Achten Sie auf die Einhaltung der zul ssigen Daten und Ein satzbedingungen insbesondere auf die zul s...

Страница 4: ...ungen etc sein Verwenden Sie niemals Ger te mit offensichtlichen Besch digungen VORSICHT Verwenden Sie geeignetes Werkzeug In bereinstimmung mit der DIN EN 1127 1 unterliegt die Handhabung und Auswahl...

Страница 5: ...en Anschl ssen versehen Vergleichen Sie die Artikelnummer auf dem Typen schild mit der Artikelnummerstruktur im Kapitel Einleitung Vermeiden Sie Mischinstallationen d h Rohrleitungen an Kunststoffk rp...

Страница 6: ...dass der Pumpenmotor die korrekte Spannung und Frequenz hat Spannungstoleranz 5 und Frequenzto leranz 2 Die Zuleitungs sowie Erdungsquerschnitte sind der Bemes sungsstromst rke anzupassen Verwenden S...

Страница 7: ...der Elastomer Zahnkranz der Kupplung nur P2 4C rich tig montiert und nicht besch digt ist die abh ngig vom Betrieb notwendigen Schutz und berwachungsvorrichtungen vorhanden und funktions f hig sind j...

Страница 8: ...d use existing material combin ations as well as pressure and temperature limits in the data sheets When installed outdoors ensure adequate protection from the weather see chapter Requirements for the...

Страница 9: ...ust automatically shut down the sample gas pump should the temperature exceed the limits DANGER DANGER Explosion danger in case of high temperat ures Temperature of the device depends on the medium te...

Страница 10: ...uld result in equipment damage CAUTION Avoid vibrations and resonances The operator is responsible to mount the pump in a way that vibrations and resonance do not cause premature failure res ulting in...

Страница 11: ...es are tight 4 4 1 Monitoring the sample gas pump NOTICE When following preventive maintenance according to the maintenance plan a crack in the bellows is a rare malfunc tion but cannot be completely...

Страница 12: ...he operation site must cor respond to all the ratings plate information 5 Operation and control NOTICE The device must not be operated beyond its specifications DANGER Danger of explosions danger of p...

Страница 13: ...When switching the sample gas pump on make sure that no abnormal sounds or vibrations occur the flow rate is neither too low nor too high This would indicate a cracked bellow 5 2 Operating the sample...

Страница 14: ...n du produit et fonctionnement et utilisation ainsi que les informations des fiches techniques concernant les usages sp cifiques les com binaisons de mat riaux pr sentes ainsi que les limites de press...

Страница 15: ...anch it des tuyaux DANGER Compression adiabatique risque d explosion L apparition de temp ratures de gaz lev es pour cause de compression adiabatique est possible et doit tre v rifi e par l utilisateu...

Страница 16: ...ez les trois vis cruciformes du couvercle de bo tier et enlevez celui ci voir im 1 im 2 Le m canisme d en tra nement est maintenant visible ATTENTION Risque d crasement Risque d crasement des doigts N...

Страница 17: ...ez que la pompe de circulation est compl te Il faut encore 6 vis M6 avec crous de longueur ad quate pour le montage Sur tous les types de pompes la t te de pompe peut unique ment tre orient e 0 et 180...

Страница 18: ...une surveillance CMT CMT Concentration maximale sur le lieu de travail sur le lieu de mise en place Manom tre de sous pression Pompe de gaz de mesure Manom tre D bitm tre Unit de coupure Fig 1 Exemple...

Страница 19: ...x gazeux peut entra ner dans le soufflet le corps de la pompe une charge lectrostatique entra nant un risque d inflammation surface projet e dans le soufflet le corps de pompe 15 cm2 DANGER Risque d e...

Страница 20: ...e r duction diminue la dur e de vie du soufflet Sur les pompes avec vanne de d rivation int gr e les perfor mances de refoulement peuvent tre r gul es N exercez pas une force excessive pour tourner la...

Страница 21: ...los cap tulos Descripci n del producto y Uso y funcionamiento as como las indicaciones descritas en las hojas de datos en re laci n al uso previsto espec fico las combinaciones de mate riales disponi...

Страница 22: ...diab tica peligro de explosi n El usuario debe comprobar si se producen altas temperaturas a causa de una compresi n adiab tica Aseg rese de que se cumplen los datos aportados y las condi ciones de in...

Страница 23: ...No utilice nunca dispositivos en los que se aprecien desperfectos CUIDADO Utilice herramientas espec ficas De acuerdo con la norma DIN EN 1127 1 la utilizaci n y selec ci n de herramientas espec fica...

Страница 24: ...para evitar que la condensaci n se escape y no se acumule en la bomba o el conducto 4 4 Conexi n de las tuber as de gas Las bombas han de estar previstas de las conexiones que ha elegido Compare el n...

Страница 25: ...gurarse contra un sobrecalentamiento no autorizado a trav s de un protector contra sobrecarga rel t rmico Tener en cuenta la corriente asignada para la configuraci n del interruptor de protecci n v as...

Страница 26: ...as La tensi n y la frecuencia del motor coincidan con los va lores de red Las conexiones el ctricas est n fijadas firmemente y los dispositivos de monitorizaci n est n conectados y confi gurados debid...

Страница 27: ...del dispositivo y recomendaciones recomendaciones en cuanto al manteni miento y la soluci n de problemas consulte las instrucciones originales que se pueden encontrar en el CD que se incluye y en Inte...

Страница 28: ...tschland 49 0 2102 4989 0 49 0 21 02 49 89 20 1 1 P2 3C P2 4C P2 3C P2 4C II 3G c IIB T4 X P2 3C P2 4C IIA IIB 80 1 2 P2 3C P2 4C 1 x 1 x 4 x 1 x 1 x 1 4301 1 x 1 x 1 x 2 a b c d a b c T4 T4 80 3 20 C...

Страница 29: ...P2 3C P2 4C 1 2 1 2 4 DIN EN 1127 1 4 1 20 C 50 C 1000 m NN d 4 1 1 4 2 P2 3C P2 3C P2 4C P2 4C 42 011 14 3 6 x M6 0 180 4 3 4 4 PTFE 29 B hler Technologies GmbH BX420022 08 2018...

Страница 30: ...P2 3C P2 4C In Out 4 4 1 UEL 4 4 1 1 4 4 1 2 1 2 1 2 UEL LEL MAK MAK 1 4 5 5 2 1 5 2 DIN VDE 0100 5 a b c d T4 15 cm2 P2 x Atex 1 30 B hler Technologies GmbH BX420022 08 2018...

Страница 31: ...P2 3C P2 4C 80 50 C 5 1 0 5 150 l h P2 4C 5 2 0 5 0 5 50 l h 150 l h 7 6 CD www buehler technologies com 7 CD www buehler technologies com 31 B hler Technologies GmbH BX420022 08 2018...

Страница 32: ...GmbH Harkortstra e 29 40880 Ratingen Deutschland 49 0 21 02 49 89 0 49 0 21 02 49 89 20 1 1 P2 3C P2 4C P2 3C P2 4C II 3G c IIB T4 X P2 3C P2 4C IIA IIB 80 1 2 P2 3C P2 4C 1 x 1 4 x 1 x 1 1 4301 1 1...

Страница 33: ...P2 3C P2 4C a b c d a b c d a b c T4 T4 80 33 B hler Technologies GmbH BX420022 08 2018...

Страница 34: ...P2 3C P2 4C 50 C 3 20 C 40 C 4 F 104 F 1 5 M 20 C 68 F 1 2 1 2 4 DIN EN 1127 1 4 1 20 C 50 C 1000 34 B hler Technologies GmbH BX420022 08 2018...

Страница 35: ...P2 3C P2 4C d 4 1 1 4 2 P2 3C P2 3C P2 4C P2 4C 42 011 14 3 6 x M6 0 180 4 3 4 4 PTFE In Inlet Out Outlet 4 4 1 OEG 35 B hler Technologies GmbH BX420022 08 2018...

Страница 36: ...P2 3C P2 4C 4 4 1 1 4 4 1 2 1 2 1 2 OEG UEG MAK 1 4 5 5 2 1 5 2 DIN VDE 0100 36 B hler Technologies GmbH BX420022 08 2018...

Страница 37: ...P2 3C P2 4C 5 a b c d T4 2 15 2 80 50 C 5 1 0 5 150 37 B hler Technologies GmbH BX420022 08 2018...

Страница 38: ...P2 3C P2 4C P2 4C 5 2 0 5 0 5 50 150 7 6 www buehler technologies com 7 www buehler technologies com 38 B hler Technologies GmbH BX420022 08 2018...

Отзывы: