4
UK
6. Connect to the mains power supply and turn
the temperature control knob on. The power
indicator light illuminates.
7. Set the Temperature Control knob to maximum
to boil the water. The power indicator light
illuminates and the appliance heats the water.
8. When not steaming food the temperature
control knob can be lowered to keep the water
warm and reduce heating times.
WARNING: If the Temperature
Control Knob is set to maximum
then the appliance will
constantly heat the water until
the Temperature Control Knob
is turned Off or the temperature
is reduced.
Thermal Cut-Out Reset
This appliance is fitted with a Thermal Cut-Out
safety feature. Should the temperature exceed safe
levels the appliance will automatically cut power.
The Safety Cut-out switch resets automatically. To
reset the appliance:
1. Disconnect from mains power supply, empty
the appliance and allow to cool.
2. The appliance is now reset and can be used as
normal.
Cleaning, Care and
Maintenance
• Always turn off and disconnect the appliance
from the power supply before cleaning.
• Use soapy water and a damp cloth to clean the
exterior and interior of the appliance, and the
steamer basket.
• Dry thoroughly after cleaning.
De-scaling
In hard water areas lime scale can build up within
the appliance after prolonged use. To de-scale the
appliance:
1. Pour a solution of de-scaler and water into the
appliance.
2. Brush the interior gently with a soft bristled
brush.
3. Discard the solution collected in the appliance.
4. Fill the appliance with clean water and turn
back On to flush out the system. Flush out the
system thoroughly to remove any de-scaler
residue.
5. The appliance is now ready for use.
Note: Use a suitable de-
scaler and always follow the
instructions on the container.
BUFFALO recommend that this
appliance is de-scaled every
month or more frequently in
hard water areas.
Troubleshooting
Fault
Probable Cause
Solution
The unit is not working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged
Call BUFFALO agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call BUFFALO agent or qualified technician
Auto re-set activated
Allow product to cool for 30 minutes
Power Indicator light
comes on but water does
not reach temperature
Thermostat fault
Call BUFFALO agent or qualified technician
CL205_ML_A5_v4_20200609.indb 4
CL205_ML_A5_v4_20200609.indb 4
2020/6/9 13:23
2020/6/9 13:23