Fault or Breakdown

Logano GB102– 6 720 811 066 (2014/09)

8

5

FAULT OR BREAKDOWN

This boiler is supported in the UK and Eire by Worcester, Bosch Group.

Specialist Service Engineers are available to attend a breakdown 
occurring on this boiler.

• No charge will be made for parts and/or labour providing: 

A boiler fault is found and the appliance has been installed within the 
last 24 months. Reasonable evidence of this must be supplied on 
request. i.e. the Benchmark Checklist.

• A call-out charge will be made where:

– The boiler has been installed for over 24 months.
– Evidence cannot be provided that the first year service inspection 

has been carried out.

– Our Field Service Engineer finds no fault with the boiler.
– The cause of breakdown is misuse or with other parts of your 

plumbing/heating system, or with equipment not supplied by 
your appliance manufacturer.

Technical Support

In the event of a boiler fault or breakdown please use the contact 
numbers on the back of this manual. 
Your advisor will arrange for an engineer to call with the minimum of 
delay; under normal circumstances this will be from 1 - 3 working days 
(excluding weekends) for priority breakdown situations (no hot water 
and/or heating).

6

ENVIRONMENT / DISPOSAL

Environmental protection is a fundamental corporate strategy of the 
Bosch Group. 
The quality of our products, their economy and environmental safety are 
all of equal importance to us and all environmental protection legislation 
and regulations are strictly observed.
We use the best possible technology and materials for protecting the 
environment taking account of economic considerations.

Packaging

We participate in the recycling programmes of the countries in which our 
products are sold to ensure optimum recycling. 
All of our packaging materials are environmentally compatible and can 
be recycled.

7

TIPS ON ENERGY SAVING

HEATING ECONOMICALLY

The boiler provides a high level of comfort whilst keeping gas 
consumption and the environment effects as low as possible.

The gas supply to the burner is controlled according to the level of 
demand for heat. The boiler operates with a low flame if the demand for 
heat reduces. The technical term for this process is modulating control.

Modulating control reduces temperature fluctuations and provides an 
even distribution of heat throughout the home. This means that the 
boiler may stay on for relatively long periods of time but will use less gas 
than a boiler that continually switches on and off.

CENTRAL HEATING SYSTEMS WITH ROOM THERMOSTAT/
THERMOSTATIC RADIATOR VALVES

With modern heating systems set around a 20 °C heat loss, the optimum 
setting for a condensing boiler will be approximately between the first 
and second segment on the central heating temperature control. The 
system must be balanced correctly and the radiators may need 
upgrading. This allows the boiler to condense as much as possible for the 
central heating system.

The temperature of each room can be set individually (except primary 
room with the room thermostat) using the thermostatic radiator valves.

ROOM THERMOSTATS

Reducing the setting of the room thermostat by 1 °C can reduce fuel 
consumption by up to 10%.

NEW CONTROL SYSTEMS

Upgrade your heating control system if necessary with the latest 
equipment available.

ROOF INSULATION

Around 30% of the heat loss from a property is through the roof. Replace 
any old insulation with new insulation, preferably of around 200mm 
thickness or more.

WINDOW FRAMES

Single glazed windows, particularly those with steel frames, can lose a 
great deal of heat. Consideration should be given to replacement with 
PVCu or wooden framed double glazed units.

RADIATORs

If a radiator is sited underneath a window, its performance will be 
affected if the curtains are allowed to drape over the radiator. Shelves 
fitted above or in front of the radiator should also be avoided.

It is advisable to manually adjust all thermostatic radiator valves 
every 2 - 3 months to prevent them sticking. 
Ensure radiator valves are correctly set and not damaged.

DRAUGHTS

Try to ensure that draughts around doors, windows, letterboxes and 
keyholes etc. are reduced by using a suitable draught excluder. 

CURTAINS

Lined curtains, or heavier full length curtains can provide excellent 
insulation. However, always ensure that the curtains do not drape over 
radiators.

Invoices for attendance and repair work carried out on 
this boiler by any third party will not be accepted.

No boiler fault is found on over 30% of all service 
calls.

In the case of a suspected fault, refer to the fault finding 
section of this guide.

USED APPLIANCES

▶ All gas boilers are 100% recycleable.

The various assemblies can be easily dismantled and 
synthetic materials are marked accordingly. 
Assemblies can be sorted by composition and passed 
on for recycling.

WARNING: 

Air vents

▶ Do not block or seal any air vents that are installed to 

ensure that the central heating boiler operates 
safely.

Содержание Logano plus GB102

Страница 1: ...Vor Installation und Wartung sorgfältig lesen User Instructions Gas fired condensing boiler Logano plus GB102 GB102S System boiler16 30 Regular boiler 16 30 42 6 720 811 066 2014 03 ...

Страница 2: ...ient offering you economical running costs and value for money It sits in SEDBUK 2005 Band A and is therefore amongst the top energy rated boilers available There is also the reassurance of our no nonsense 2 years parts and labour guarantee backed up by Worcester Total Cover an optional complete maintenance scheme to keep your boiler operating at peak condition and efficiency Table of Contents 1 K...

Страница 3: ...SERVICING Advise the user to have the system serviced annually by a competent qualified Gas Safe registered engineer Approved spares must be used to help maintain the economy safety and reliability of the appliance IMPORTANT The service engineer must complete the Service Record on the Benchmark Checklist after each service 2 PRODUCT INFORMATION 2 1 Intended use The appliance is only for use in sea...

Страница 4: ... compensation External sensor required 5 Chimney sweep mode 6 Fault alert 7 Service mode 6 7 Maintenance mode 8 Burner on 9 Temperature units C 10 Confirmation 11 Scroll up or down through the sub menus 12 Alphanumeric display e g Temperature 13 Text display 14 Heating mode off 15 Heating mode on 3 3 Appliance on off switch Initial switch on Switch on at the with the main appliance switch The disp...

Страница 5: ...the button The display shows the flashing maximum flow temperature and the Heating mode symbol is displayed Fig 6 Maximum flow temperature Press the or button to set the desired maximum flow temperature Press ok to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 7 Setting the maximum flow temperature The controller has a pump anti seize function...

Страница 6: ...t temperature The control then switches back into heating mode 3 5 2 Setting the DHW temperature DHW or Eco mode page 6 Press the button The set DHW temperature flashes Fig 10 Pressthe or button toselectthedesiredDHWtemperature set between 40 and 60 C Press the ok button to save the setting The tick symbol is displayed briefly to confirm that the setting has been saved Fig 11 3 6 Control unit sett...

Страница 7: ...rol system manual Cylinder frost protection Even when the DHW mode is switched off the cylinder is protected against frost damage Set the DHW mode to off Section 3 5 1 4 SYSTEM OPERATING PRESSURE 4 1 Check the water pressure System boiler only The normal operating pressure is between 1 and 2 bar If the pressure needs to be constantly re pressurized or the pressure is constantly over the 2 5bar mar...

Страница 8: ... for relatively long periods of time but will use less gas than a boiler that continually switches on and off CENTRAL HEATING SYSTEMS WITH ROOM THERMOSTAT THERMOSTATIC RADIATOR VALVES With modern heating systems set around a 20 C heat loss the optimum setting for a condensing boiler will be approximately between the first and second segment on the central heating temperature control The system mus...

Страница 9: ... ok button to save the setting The tick symbol is displayed briefly to confirm the setting Setting the optional control system See operating instructions for the control systems Setting the maximum flow temperature Press the button Press the or button the set the flow temperature Setting the DHW temperature Press the button Press the or button to set the DHW temperature Press the ok button to save...

Страница 10: ...8 Logano GB102 6 720 811 066 2014 09 10 Notes ...

Страница 11: ...8 Logano GB102 6 720 811 066 2014 09 11 Notes ...

Страница 12: ......

Отзывы: