background image

Instructions for High Altitude Conversion

2

We reserve the right to make any changes due to technical modifications!

Instructions for high altitude conversion for sealed combustion gas boiler GA124 • Issue 

03/2005

Buderus Heiztechnik GmbH • http://www.heiztechnik.buderus.de

1

Safety Considerations

Please observe the following safety instructions.

1.1

Application purpose

This kit and instructions are for high altitude converting 
the GA124 model boiler over 

85

00 ft.

1.2

Guideline of Notices

Two levels of danger are identified by the following 
warning labels:

1.3

Observe the following symbols

2

Parts List for High Altitude 
Conversion

This kit contains the following parts:

Main orifices and gaskets.

Conversion data plate to be filled out and affixed to 
the appliance.

Conversion instructions.

Technical documents.

WARNING!

DANGER

Denotes a possible severely dangerous 
situation where, without proper caution, 
bodily injury or loss of life may result.

WARNING!

DANGER

due to electricity.

APPLICATION NOTICE

Application comment for optimum use of 
equipment and adjustment as well as useful 
information.

WARNING!

DANGER

due to explosion of gas.

Work only on gas components when
you have a license to do so.

Note that the assembly of gas and vent 
connections, the initial start-up, the 
electrical connections, the 
maintenance and service can only be 
performed by a licensed service 
contractor or technican.

WARNING!

DANGER

due to electricity.

Prior to doing any work on the heating 
system, disconnect all electrical power 
to the boiler at the emergency switch.

It is NOT sufficient to shut off only the 
boiler control!

Содержание Logano GA124-17

Страница 1: ...nstalled by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction and in accordance with the requ...

Страница 2: ...Conversion data plate to be filled out and affixed to the appliance Conversion instructions Technical documents WARNING DANGER Denotes a possible severely dangerous situation where without proper caut...

Страница 3: ...3 Remove jacket panel screws Fig 1 Item 1 from left and right side tilt forward top of front jacket panel Fig 1 Item 2 then lift up from the bottom and remove 4 Turn the gas control manual knob Fig 2...

Страница 4: ...he flame roll out switch Fig 4 Item 3 10 Remove the burner tray cover plate screws and remove this cover plate Fig 4 Item 4 11 Remove burner tray mounting nuts Fig 4 Item 1 and take entire burner tray...

Страница 5: ......

Страница 6: ...ter to measure the supply pressure 26 Remove the manifold pressure tapping plug Fig 7 Item 3 from the gas control Install a test fitting and hook up a manometer to measure the manifold pressure 27 Ope...

Страница 7: ...ll not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water...

Страница 8: ...and then the main burners should light If the main burners do not light shut off the main gas piping shutoff valve Shut off all electric power to the appliance and call your service technician or gas...

Страница 9: ...urner flame Fig 11 Item 1 through the viewing port Fig 8 Item 1 in the burner cover plate The flame should have a smooth firm contour and must be mostly blue in color If the main flame is satisfactory...

Страница 10: ...essure tabs in the gas control and replace the plugs 19 Repeat steps 1 to 6 and 13 to place the appliance back in operation Check the plugs in the gas control with a soap and water solution If no leak...

Страница 11: ...rve the right to make any changes due to technical modifications Instructions for high altitude conversion for sealed combustion gas boiler GA124 Issue 03 2005 Buderus Heiztechnik GmbH http www heizte...

Страница 12: ...3 552 1100 Fax 603 584 1681 www buderus net BBT North America Corporation reserves the right to make changes without notice due to continuing engineering and technological advances Heating Contractor...