Page 23
FINAL CHECK
1. Recheck specified clearances.
2. Remove all foreign material from firebox area.
3. Open primary air draft and damper bypass.
4. Plug power cord into a 115V AC
outlet. Set switch to “Manual” and rheostat to “High” position to ensure
motor operates properly.
5. Place crumpled pieces of newspaper in stove. Light it and close door. Ensure that stove draws properly
through primary draft.
6. Check for smoke leaks around door.
7. Open door and check for smoke escaping from front of stove. Smoking usually indicates defective or poorly
positioned chimney. Some chimneys with a marginal draft can be preheated by lighting newspaper and
holding it near open damper with a poker or fire tong. Once the chimney heats up, a proper draft can usually
be obtained.
If a thorough review of Troubleshooting Guide in manual does not reveal problem, contact your dealer for
assistance.
NOTE: The unit is painted with a specially formulated high temperature paint that cures during first two or three
firings. You may notice a slight smoking effect and an odor of burning paint when you build first fires. This is
normal and is not a cause for alarm. In some cases, these fumes will activate a smoke alarm. Opening a window
near the unit will allow these fumes to escape. DO NOT build a large, roaring fire until this curing is complete or
the heater finish may be damaged.
FIGURE 5
2FT.
RAIN CAP
STORM COLLAR
FLASHING
NEW BUCK
CORP.
FIRESTOP
RADIATION
SHIELD
2FT.
RAIN CAP
STORM COLLAR
FLASHING
NEW BUCK CORP.
FIRESTOP RADIATION
SHIELD
3 FT.
TYPICAL
20 FT.
MAX.
TYPICAL
Содержание MODEL 20
Страница 2: ......