BuckMaster FP-BR-10-ZC Скачать руководство пользователя страница 39

OWNER REGISTRATION 

 

The attached owner registration card must be completed in its entirety and mailed within 30 
days from date of installation in order for warranty coverage to begin to: 
 
 

 

 

 

New Buck Corporation 

    P.O. 

Box 

69 

    Spruce 

Pine, 

NC 

 

28777 

 
PLEASE NOTE:  Owner Registration Card must contain Authorized Buck Stove Dealer 
Number and Certified Installer’s number (if applicable) for warranty coverage to begin. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAME: _____________________________________________________  

ADDRESS: __________________________________________________  

CITY: ______________________________________________________  

STATE: ______________________   ZIP:  ________________________  

MODEL #:  FP-BR10ZC   SERIAL #:  ___________________________  

DATE OF INSTALLATION:  ___________________________________  

INSTALLER’S NAME: ________________________________________  

PURCHASED FROM:  ________________________________________  

 

 

 

 

 

 

 

Содержание FP-BR-10-ZC

Страница 1: ...heater It uses air oxygen from the room in which it is in stalled Provisions for adequate combustion and ventilation air must be provided Refer to section Producing Adequate Air For Combustion And Ve...

Страница 2: ......

Страница 3: ...ion 11 Mobile Home Installation 13 Gas Connection 13 Producing Adequate Air for Combustion and Ventilation 14 Air For Combustion And Ventilation Air Iinside Building 16 Air For Combustion And Ventilat...

Страница 4: ......

Страница 5: ...directly in front of heater pulling from either direction may create sooting Sooting will discolor walls 1 The installation must conform with local codes or in absence of local codes with National Fue...

Страница 6: ...must be closed 12 Keep appliance area clean and free from combustible materials gasoline and other flammable flammable vapors and liquids 13 If burner shuts off do not relight until you provide fresh...

Страница 7: ...y away to avoid burns or clothing ignition 27 Young children should be carefully supervised when they are in same room with appliance 28 An unvented room heater having an input rating of more than 6 0...

Страница 8: ...and hot air grills may cause the flames to soot If a disturbance is found that affects the flames it must be eliminated by turning off ceiling fan closing the door or closing or moving th hot air reg...

Страница 9: ...hould be performed by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exces...

Страница 10: ...cureFirebox Secure fireplace to framing The nailing flanges on firebox will make securing firebox to frame quick and easy Use appropriate sizenailsor screwsto securefirebox FIREPLACECLEARANCES The fir...

Страница 11: ...ce opening Check to see whether man made brick and stone are made of non combustible materials before using them on face of fireplace Some of these products contain combustible materials Combustible w...

Страница 12: ...r Support must be Flush with top of Unit if mantel is 10 wide or less 12 2 1 2 3 4 3 3 1 2 Bottom of 3 4 Base or Support must be at least 2 1 2 from top of Unit if mantel is 10 wide or more 3 4 3 1 2...

Страница 13: ...osed position before leaving heater unattended 3 Follow instructions for assembly of Optional Wooden Mantel See instructions supplied with mantel 4 After mantel has been assembled slide heater from re...

Страница 14: ...Page 12 FIGURE 6 MANTEL BASE TOP MANTEL REAR OF HEATER 1 2 WOOD SCREWS 9...

Страница 15: ...ment trap piping check local codes tee joint manual shutoff valve pipe wrench test gauge connection sealant resistant to LP gas WARNING ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS INSTA...

Страница 16: ...HEATER MAY BE OPERATED DOES NOT MEET REQUIRED VOLUME FOR INDOOR COMBUSTION AIR COMBUSTION AND VENTILATION AIR SHALL BE PROVIDED BY ONE OF METHODS DE SCRIBED IN NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA...

Страница 17: ...me of space 50 cu Ft 51 2 or 51200 maximum BTU Hr space can support 3 Add BTU Hr of all fuel burning appliances in space Vent free heater _______________BTU Hr Gas water heater _______________BTU Hr G...

Страница 18: ...re inch per 1000 BTU s per hour of total input ratings of all gas utilization equipment in confined space but not less than 100 square inches Figure 7 Ventilation Air From Inside Building A Rework wor...

Страница 19: ...ustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet air into attic if attic has a thermostat controlled power vent Heated air entering a...

Страница 20: ...psi 3 5 kPa MODEL FP BR10 ZC FP BR10 ZC Gas Natural Propane Maximum Heat Input 10000 10000 Gas Inlet Pressure Maximum 10 5 ins W C 13 ins W C Minimum 5 ins W C 11 ins W C Manifold Pressure 3 5 ins W C...

Страница 21: ...minated after first few hours of operation Do not use blower at this time Front View of Logs WARNING FAILURE TO POSITION PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICAL...

Страница 22: ...gas supplier from a neighbor s phone Follow gas supplier s instructions If you cannot reach your gas supplier call your local fire department C Use only your hand to push in or turn the gas control kn...

Страница 23: ...nd in front of rear log Fully open manual shut off valve 9 Turn control knob counterclockwise to PILOT position Press in control knob for 15 fifteen seconds see figure 3 10 With control knob pressed i...

Страница 24: ...er of base for access to control knobs 2 Turn control knob clockwise to PILOT position 2 Close access panel door CAUTION Hot while in operation Do Not Touch Keep children clothing furniture gasoline a...

Страница 25: ...to determine your personal comfort levels MANUAL LIGHTING PROCEDURE 1 If the pilot cannot be ignited with igniter on the control valve it can be manually lit with use of a paper match and a lighter r...

Страница 26: ...resent when gas logs are in operation FLAME Propane LP should produce a flame that is 3 4 above rear log This flame should be yellow Natural gas should produce a flame that is 3 4 above rear log This...

Страница 27: ...e as supplied with appliance must be replaced it must be replaced with a wire of at least a 105o C temperature rating NOTE Installation and repair should be done by a qualified service person This hea...

Страница 28: ...DING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE NOTE PESBRO84 Blower Motor Rating 120 volts 60HZ 0 54 Amps 1 P H NOTE...

Страница 29: ...LOGS OR OTHER PARTS OF THE HEATER BE SURE TO READ ABOVE SECTIONS ON IMPORTANT SAFEGUARDS The appliance must be turned OFF before cleaning inside firebox burn area make sure pilot is OFF completely and...

Страница 30: ...zo igniter nut is loose 6 Broken igniter cable 7 Bad piezo igniter 1 Gas supply turned off or manual shutoff valve is closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in...

Страница 31: ...artially clogged ODS Pilot 7 Control valve damaged 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged 5 Contact local propane gas co...

Страница 32: ...old if equipped with this type of valve 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice 1 Clean burner See Clean ing and Maintenance or replace burner...

Страница 33: ...room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and control all leaks See Checking Gas Connections 1 Open window door for ventilation 2 Contact local propa...

Страница 34: ...ng any service operation Check for gas leaks after servicing REPAIR PARTS A parts list with exploded view follows Always include correct name part number and model number of heater when ordering servi...

Страница 35: ...00 433 Thermo couple Copreci 1 7 PE 21500053 Copreci ODS Nat Pilot 1 7A PE 2150054 Copreci ODS LP Pilot 1 8 PE RV12LF30 Maxitrol Regulator Nat 1 8A PE RV12LF90 Maxitrol Regulator LP 1 9 RF 14ALMTUB 1...

Страница 36: ...Page 34 BLOWN UP VIEW OF BURNER ASSEMBLY 16 Not shown on this page See page 25 figure 10 for wiring diagram...

Страница 37: ...to parts that are not in original condition normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installa...

Страница 38: ......

Страница 39: ...rtified Installer s number if applicable for warranty coverage to begin NAME _____________________________________________________ ADDRESS __________________________________________________ CITY _____...

Отзывы: