Page 11
HOW TO LOCATE CHIMNEY EXIT AND INSTALL
Residential and Mobile Home Installation
C. Vertical Exit using (6" DVL Close Clearance pipe and any Listed 2100° UL 103 HT
chimney). With optional close clearance shield and pipe shield.
NOTE: For installation of optional pipe shield (See Page 23).
NOTE: For minimum clearances (See Page 12, Figure 8).
For Required Out Side Air in Mobile Homes (See Page 15).
1. Suspend a plumb bob from ceiling above unit so that weight is hanging in center of flue
exit. (A small weight on a string will serve as a plumb bob). Mark ceiling where string is
suspended to locate center of the chimney.
2. After locating center of hole, install ceiling support box, chimney or chimney connector,
flashing and rain cap, per chimney manufacturer’s instructions and local building codes
for installation through combustible walls or ceilings.
3. Now connect stove and ceiling support box using DVL close clearance pipe. Connect
each section, per manufacturer’s instructions. Secure each section to each other using
minimum (3) sheet metal screws or rivets.
DVL close clearance is to be connected with (3) sheet metal screws or rivets to
connector collar on heater (See Page 12,Figure 9).
If appliance is installed in mobile homes:
WARNING:
DO NOT INSTALL IN SLEEPING ROOMS.