5. Wiring
For Devices that Operate on 12 Volts and 5 to 20 Amps
Wire Color
Connection
Description
Red
+12 Volts
+12 Volts from battery that is inside of Auxiliary Relay Pack
Black
-12 Volts
-12 Volts from battery that is inside of Auxiliary Relay Pack
Brown
Relay contact
One side of the Normally Open relay
Blue
Relay contact
One side of the Normally Open relay
1. Install a UB1270 Sealed Lead Acid battery inside of the Auxiliary Relay Pack.
2. Connect the cables as shown below.
3. Connect the Red and Blue wires with supplied wire nut as shown below.
4. Connect the Brown wire to the device positive terminal (+).
5. Connect the Black wire to the device negative terminal (-).
X80 Activator User's Manual v1.2 9