To adjust the other head pumps, press the ESC key to access the selection screen or to return to the previous
menu.
NOTE:
Although you can set the starting time for various pump to be the same, the system is calibrated to deliver
each dosages at different intervals. When there is a time overlap, the pump is readjusted for each 5-minute intervals.
For example, when all three pumps can be set to 01:00 start, PUMP1’s start time is at 01:00, but PUMP2’s actual start
time is at 01:05; and PUMP3’s actual start time is at 1:10).
5.
To Finish
After everything is set up, press ESC until the screen shows the current clock (time is in 24hr intervals, not
12hr).
Your settings will take effect automatically.
Expansion unit configuration:
The BM-T01 has a back panel that allows it to connect with the BM-T02 extension pump unit. The expansion unit
can unlock "SETUP P 4-7" and "SETUP P 8-11" configurations for additional pump head control.
Table: The total dosage that can be administered how many times a day.
Total Dosage (ml)
Cycles per day
1
1, 2
2
1, 2, 3, 4
3
1, 2, 3, 4, 6
4, 5
1, 2, 3, 4, 6, 8
6-11
1, 2, 3, 4, 6, 8, 12
12-160
1, 2, 3, 4, 6, 8, 12, 24
161-319
2, 3, 4, 6, 8, 12, 24
320-479
3, 4, 6, 8, 12, 24
480-639
4, 6, 8, 12, 24
640-959
6, 8, 12, 24
960-1279
8, 12, 24
1280-1919
12, 24
1920-1999
24