2.
The screen will show PUMP01. Press UP or DOWN to select from PUMP01-PUMP11.
3.
After selecting the desired pump head. Press and hold the ENTER key to activate the flow of liquid.
Release the button to stop operation.
4.
Press ESC to exit the manual control mode.
NOTE:
Without the expansion unit (BM-T02), the BM-T01 dosing pumps should only show PUMP01, PUMP02, and
PUMP03.
Program control mode:
Below is an overview of the procedure for adjusting the pump’s total dosage, frequency of delivery, and starting time.
1.
Pump Selection
In the initial state, press ESC key. Press the UP or DOWN to select SETUP PROGRAM
Press ENTER. The screen will display the group of head pumps to adjust, like SETUP P 1-3.
Press ENTER. The screen will display the individual pump for configuration, like SETUP PUMP 1.
Press the UP or DOWN key to select the desired pump.
2.
Total Dosage Quantity
After selecting the desired pump, select the daily amount of liquid to add (range of 1 ~ 1999ml) per 24 hours. The
figure to the right shows PUMP1 as being selected.
At this point:
Select the dosage quantity (ml) by pressing UP or DOWN to change the value of the selected digit.
Press the ENTER key to advance to the next digit.
Example: P 1:0888 signifies that in 24 hours, PUMP1 will add 888ml wroth of solution.
3.
Frequency (cycles per day)
After confirming the total dosage, the user may then select the frequency of the dosage per 24 hours.
The screen to the right, CYCL / DAY P1 8, shows the total dosage being pumped 8 times a day (every 3hrs).
Press UP or DOWN to change the number.
Press ENTER to confirm.
NOTE: ‘24’ points is the maximum value (total dosage is delivered in the increments of once per hour, 24 time
a day). In contrast, ‘1’ is the minimum value (total dosage is delivered all at once, 1 time a day).
4.
Set Start Time
After confirming the frequency of dosage, the user may set the start time.
The default screen is START: 00:00.
Press UP or DOWN to adjust the set of digits, ranging from 00 to 23.
Press ENTER to confirm and to proceed to the next set.
After finalizing your hour and minutes, press ENTER again.
The screen will display Saving ..., stating that your settings are being saved per pump head.
Press the ENTER key to confirm.
SETUP
PROGRAM
ml/DAY
P 1:0000
CYCL/DAY
P 1 8
START
:
00:00