2.

 

Connect the hose connectors to the inlet and outlets tubes of each pump head as illustrated above.       

3.

 

Proceed to connect the PVC line to each connector.    Each PVC line should be cut to the appropriate length of 
your configuration.     

4.

 

When facing of the pump heads, the PVC line connected to the inlet port on the left side needs to be routed to 
your supply of additives.    Whereas, the line connected to the right outlet should be routed to your tank.   

NOTE: The pump is designed for aquarium additives only.    Strong acids or other chemicals like alkali 
solutions are not suitable.

     

 

5.

 

Lastly, connect the power transformer/supply to the unit.    Double check all your connections to ensure that 
they are safe and secure.         

6.

 

Turn on the unit.    The screen should show the clock as 00:00:00 (initial state).   

  Clock settings:   

1.

 

In the initial state, press ESC key, and then press the UP or DOWN button until the screen display SETUP 
CLOCK.
   

2.

 

Press the ENTER button to access the clock setting mode.    Press UP or DOWN to increase or decrease the 
values. 

3.

 

Press ENTER to confirm and proceed to the next digit. 

4.

 

To finalize your adjustments, press ENTER again to exit the clock adjustment 

   Manual control mode (for priming or testing): 

1.

 

In the initial state, press ESC, select MANUAL CONTORL, and press ENTER.   

Bubble-Magu

s

00:00:0

SetClock 

10:00 

MANUAL 

CONTOR

 

Содержание BM T-01

Страница 1: ...ddition this product has a data protection feature In the case of a power outage blackout or brownout the BM T01 can retain its settings up to 24 hours Thank you choosing BUBBLE MAGUS Please read the instructions carefully before use If you encounter any issues whether it is in the packaging during your installation or during normal operation of your product contact support seasideaquatics com for...

Страница 2: ...ot suitable 5 Lastly connect the power transformer supply to the unit Double check all your connections to ensure that they are safe and secure 6 Turn on the unit The screen should show the clock as 00 00 00 initial state Clock settings 1 In the initial state press ESC key and then press the UP or DOWN button until the screen display SETUP CLOCK 2 Press the ENTER button to access the clock setting...

Страница 3: ...ected At this point Select the dosage quantity ml by pressing UP or DOWN to change the value of the selected digit Press the ENTER key to advance to the next digit Example P 1 0888 signifies that in 24 hours PUMP1 will add 888ml wroth of solution 3 Frequency cycles per day After confirming the total dosage the user may then select the frequency of the dosage per 24 hours The screen to the right CY...

Страница 4: ...0 5 To Finish After everything is set up press ESC until the screen shows the current clock time is in 24hr intervals not 12hr Your settings will take effect automatically Expansion unit configuration The BM T01 has a back panel that allows it to connect with the BM T02 extension pump unit The expansion unit can unlock SETUP P 4 7 and SETUP P 8 11 configurations for additional pump head control Ta...

Отзывы: