INSTRUCTIONS FOR USE | PAGE 11 OF 62
Notes:
E1
connector for connection of electrotherapy accessories (BTL-236-1(2), BTL vac) to the
E1
generator
E2
connector for connection of electrotherapy accessories (BTL-236-1(2), BTL vac) to the
E2
generator
E1opti
connector for connection of electrotherapy cables (BTL-226, BTL vac) to the
E1
generator
E2opti
connector for connection of electrotherapy cables (BTL-226, BTL vac) to the
E2
generator
E1A, E1B
connector for connection of electrotherapy accessories (BTL-236-1(2), BTL vac) to the double
generator E1
L1A, L1B
connector for connection of laser probe/ cluster BTL-448 / BTL-445 to the
L1
generator
L2A, L2B
connector for connection of laser probe/ cluster BTL-448 / BTL-445 to the
L2
generator
U1A, U1B
connector for connection of ultrasound head BTL-237, e.g. 1 / 4 cm
2
, to the
U1
generator
M1A, M1B
connector for connection of magnetotherapy applicators (BTL-239) to the M1 generator
E input
connector for input of external electrotherapy
BTL-46xx, BTL-56xx
on the ultrasound device at
combined
therapy
E output
connector for output of external electrotherapy
BTL-46xx, BTL-56xx
on the ultrasound device at
combined
therapy
door
connector for the open door sensor
acup. c
onnector for the acupuncture electrode
How many patients and which outputs you can simultaneously connect to can be seen on the display after
pressing the
menu
key, in
menu / accessories / connectors – information
.
2.5 OPERATING THE UNIT
The display contains several graphic elements. Some of them are only for information, some can be activated.
The basic elements are the following:
•
buttons (it is possible to activate them by the
tab
key
(15)
and to change their values.) The activated
buttons are displayed inversely.
•
information
texts
•
channel tabs (switching between the tabs, selection)
The buttons can be enabled or disabled. The disabled buttons are crossed out.
All the displayed enabled buttons can be successively activated by pressing the
tab
key
(15)
. By repeated
pressing of this key further buttons on the screen are successively activated.
If the button contains one numeric value, this value can be directly changed by the
select/intensity
knob
(12)
. If
the button contains more numeric values or an item selected from a list, pressing of the
enter
key
(13)
opens the
detailed subscreen of the button. In the bottom right corner of the selected parameters screens there is a button
shaped like a folded corner of paper. It has the same function as the
NEXT
key (
16
) and opens the parameters
subscreens. To leave the subcscreen press
esc (14)
– all data you have changed will remain changed.
Information texts
The text is displayed directly on the display, in a menu or in a button. If a text is too long and does not fit on the
display in full, after a while it starts scrolling automatically.
Selected channel
Although most of the devices of the BTL-4000 Series can run more therapies at a time, only one channel can be
controlled at the particular moment. That channel is called the "selected channel". The tab of the "selected
channel" in the bottom part of the screen is coloured dark. All information on the screen and all controls are relate
to this channel. The most important information about the therapies on the other channels remains visible on their
tabs.