![background image](http://html.mh-extra.com/html/bticino/349416/349416_installation-manual_2825508008.webp)
Alarms Notification Module
8
4 CONFIGURATION
•
The Alarms Notification Module is capable of handling 8 independent contacts and
one additional contact dedicated to panic alarm signals (PANIC). Each contact can
be enabled and disabled; its state (enabled/disabled/alarmed) is shown by the rel-
evant LED (for the meaning of the various signals, refer to the User Manual, on the
“LEDs light signals” section).
•
The contacts can serve different purposes, depending on their configuration. In
their basic configuration, contacts 1 to 5 handle burglar alarms, and contacts 6 to 8
are for the three technical fault alarms: gas leak, fire and flooding.
•
All 8 alarm contacts should be treated as independent zones. They can be choked by
disabling their channel. The PANIC contact, which can also be choked, is dedicated to
the connection with a panic or remote assistance alarm.
•
Each apartment can have only one Alarms Notification Module. The device configura-
tion is done using three configurators (MOD, T1 and T2), depending on the system:
the inputs, the alarm time delays or the address of the flat.
4.1 MODE SELECTION
4.1.1 SYSTEM WITH APARTMENT INTERFACE, ITEM346850
ON
346850
INT
EXT
ON
OFF
CE:3)
CE:3&½)
We recommend that the “Alarm Notification Module Configuration”
table, which can be found in chapter 1 of the User Manual, is filled
in all its parts, once the configuration is completed.