1
6 CHECKING THAT THE SYSTEM IS WORKING CORRECTLY
•
When the Alarms Notification Module receives a panic alarm signal, the buzzer will
emit an acoustic signal for 10 seconds (fixed delay). The signal will then be sent to the
Handset and to the Switchboard (irrespective of the actual state of the panic button).
•
After sending the notification, the acoustic signal will stop, the LED of input
9
will con-
tinue to stay on, but flashing will become slow.
Anti-tamper alarm
•
Generate a tamper alarm by opening the tamper protection.
•
The “
P
” LED will start flashing slowly.
4 Cancelling alarms
•
To remove the visual notification of the alarm, press the button of the input that gen-
erated the alarm.
•
To also remove the alarm signal from the Handset and the Switchboard, press the
o¬
button and enter the
codice
(1245) or run the
Trasponder
by the reader.
•
For technical faults alarms, before cancelling the alarm notification, the alarm situation
must be terminated.