manualshive.com logo in svg
background image

6

346812

15/10/2013

BT00653-a-

PIVOT 4 key 

handset accessory

EN

230 Vac

PS

BU S

TK

BU S

PI

1

2

3

4

1

2

3

4

2

2

2

2

2

1

2

3

4

346830

N

P

3

N

P

2

N

P

1

2

1

O

BUS 2 1

BUS

MOD=3

P=0

P=1

PE

PE 

local

Power supply 346000

BUS

MOD=3

MOD=3

clack

clack

ON

346850

IN T

EXT

ON

OF F

2 wire

riser

N =  8

M =  3

main

Local 
door lock

IP30

PRI

PRI 230 V~ 50 - 60 Hz  260 mA

346000

}

BUS

2 - 1

27V      1,2A

CEBEC

N

N F

Auto-switching on of the local EP
door lock of local EP
intercom call to N=1
intercom call to N=2

Auto-switching on of the local EP
door lock of local EP
intercom call to N=1
intercom call to N=3

Auto-switching on of the local EP
door lock of local EP
intercom call to N=2
intercom call to N=3

Apartment 8

Configuration

Example 7 - MOD = 3 (mixed mode) with 346850

For systems with apartment interface 346850

- Key 

1

 Auto-switching on and cycling of local EPs

- Key 

2

 Activation of the door lock of the local EP directly without call

- Key 

3

 Intercom function among the apartment handsets

- Key 

4

 Intercom function among the apartment handsets

Содержание 346812

Страница 1: ...mode M Operating mode It sets the operating mode allocated to the individual keys of the accessory block The mode changes depending on whether the apartment interface 346850 has been installed or not...

Страница 2: ...onfigured with MOD 5 and P P 3 4 346200 configured with MOD 5 and P P 4 Door lock actuator 346230 346260 1 Actuator configured with P 1 2 Actuator configured with P 2 3 Actuator configured with P 3 4...

Страница 3: ...c 230V a c 230V a c 230V a c BUS MOD 0 346200 346200 346200 MOD 9 P 1 MOD 9 P 3 MOD 9 P 4 Main PE Power supply 346000 346200 MOD 9 P 2 230V a c BUS BUS IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2...

Страница 4: ...ys call in succession the apartments configured with N 1 N 2 N 3 N 4 Activation of additional door locks Handset with N 1 Call to the Pushbutton 1 1 Handset 2 Pushbutton 2 2 Handset 3 Pushbutton 3 3 H...

Страница 5: ...1 door lock of EP P 1 intercom call to N 2 intercom call to N 3 NOTE The operating mode of the intercom function is the same as explained in example 2 In this case however the intercommunication is o...

Страница 6: ...local EP door lock of local EP intercom call to N 1 intercom call to N 2 Auto switching on of the local EP door lock of local EP intercom call to N 1 intercom call to N 3 Auto switching on of the loc...

Страница 7: ...PE main PE main P 1 Power supply 346000 BUS MOD 7 N P 1 2 N P 1 Apartment 2 N P 2 Apartment 1 2 2 2 PE audio P 2 P 2 4 O O O O P 2 P 1 P 0 IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2 1 27V 1 2A CE...

Страница 8: ...key 4 to switch the selected sound source off and activate the audio on the loudspeakers Once the handset has been replaced the sound source comes on again 230 Vac 2 N P 3 MOD 7 P 0 PE main N P 2 2 B...

Страница 9: ...9 02 346812 15 10 2013 BT00653 a Assembly Installation PIVOT 4 key handset accessory EN...

Отзывы: