2
346812
15/10/2013
BT00653-a-
Configuration
Selection of MOD configurators
MODE FUNCTION OF KEYS WITHOUT 346850
FOR MULTI-FAMILY SYSTEMS WITHIN THE APARTMENT WITH 346850
MOD =
3
1
Auto-switching on of EPs configured with P+1
1
Auto-switching on of local entrance panels
2
Door lock control for EPs configured with P+1
2
Door lock control for the local EP (direct mode)
Keys
3
and
4
for intercom among the handsets
Keys
3
and
4
for intercom among the handsets of the
of different apartments config. with N=1-3
apartment configured with N=1-3
MOD =
5
Control of door lock relay with:
Actuator for generic loads (346200)
1
346200 configured with MOD=5 and P=P+1
2
346200 configured with MOD=5 and P=P+2
3
346200 configured with MOD=5 and P=P+3
4
346200 configured with MOD=5 and P=P+4
Door lock actuator (346230 - 346260)
1
Actuator configured with P=1
2
Actuator configured with P=2
3
Actuator configured with P=3
4
Actuator configured with P=4
MOD =
6
Keys
1
,
2
and
3
for intercom among handsets
configured with N=1 - 4
4
Paging function
MOD =
7
1
Intercom among apart. devices (general call)
(two-family
2
Intercom with devices of other apart. (general call)
installations)
3
Door lock control for EPs config. with P+1
Door lock control for EPs config. with P+2
MOD =
7
1
Intercom within the same apartment
(multy-family
2
NOT USED
installations
3
Door lock control for EPs config. with P+1
config. with N = 3)
4
Door lock control for EPs config. with P+2
MOD =
9
Scenario central unit control (F420) A=0 and PL=1
1
Activate scenario 1
2
Activate scenario 2
3
Activate scenario 3
4
Activate scenario 4
PIVOT 4 key
handset accessory
EN